SciTePress - Publication Details
loading
Papers Papers/2022 Papers Papers/2022

Research.Publish.Connect.

Paper

Paper Unlock

Authors: Tomas Bodnár 1 and Adelia Sequeira 2

Affiliations: 1 Czech Technical University in Prague, Czech Republic ; 2 Instituto Superior T´ecnico and Technical University of Lisbon, Portugal

Keyword(s): Blood, Viscoelastic Model, Coagulation, Finite-volume, Runge-Kutta.

Abstract: This paper presents selected numerical results obtained using a macroscopic blood coagulation model coupled with a non-linear viscoelastic model for blood flow. The governing system is solved using a central finitevolume scheme employing an explicit Runge-Kutta time-integration. An artificial compressibility method is used to resolve the pressure. A non-linear TVD filter is applied for stabilization. A simple test case of blood flow over a clotting surface in a straight 3D vessel is solved. This work merges and significantly extends our previous studies (Bodnár and Sequeira, 2008) and (Bodnár et al., 2011a).

CC BY-NC-ND 4.0

Sign In Guest: Register as new SciTePress user now for free.

Sign In SciTePress user: please login.

PDF ImageMy Papers

You are not signed in, therefore limits apply to your IP address 8.209.245.224

In the current month:
Recent papers: 100 available of 100 total
2+ years older papers: 200 available of 200 total

Paper citation in several formats:
Bodnár, T. and Sequeira, A. (2013). On the Implementation of a Non-linear Viscoelastic Model into Coupled Blood Flow-biochemistry Model. In Proceedings of the 3rd International Conference on Simulation and Modeling Methodologies, Technologies and Applications (SIMULTECH 2013) - BIOMED; ISBN 978-989-8565-69-3; ISSN 2184-2841, SciTePress, pages 652-657. DOI: 10.5220/0004621306520657

@conference{biomed13,
author={Tomas Bodnár and Adelia Sequeira},
title={On the Implementation of a Non-linear Viscoelastic Model into Coupled Blood Flow-biochemistry Model},
booktitle={Proceedings of the 3rd International Conference on Simulation and Modeling Methodologies, Technologies and Applications (SIMULTECH 2013) - BIOMED},
year={2013},
pages={652-657},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0004621306520657},
isbn={978-989-8565-69-3},
issn={2184-2841},
}

TY - CONF

JO - Proceedings of the 3rd International Conference on Simulation and Modeling Methodologies, Technologies and Applications (SIMULTECH 2013) - BIOMED
TI - On the Implementation of a Non-linear Viscoelastic Model into Coupled Blood Flow-biochemistry Model
SN - 978-989-8565-69-3
IS - 2184-2841
AU - Bodnár, T.
AU - Sequeira, A.
PY - 2013
SP - 652
EP - 657
DO - 10.5220/0004621306520657
PB - SciTePress