Abstract
We previously developed a dynamic 4D anthropomorphic breast phantom, which can be used to optimize contrast-based breast imaging systems, accounting for patient variability and contrast kinetics [1]. In this study we aim to compare the performance of contrast-enhanced mammographic and tomosynthesis imaging protocols followed by temporal subtraction and dual-energy subtraction, qualitatively and quantitatively across a couple of patient models. Signal-difference-to-noise ratio (SDNR) is measured for the six paradigms of contrast enhanced, temporally subtracted, and dual-energy subtracted mammography and tomosynthesis and compared. The results show how the performance is more dependent on the breast model in mammography than in tomosynthesis. Also, it is observed that dual-energy subtraction can be beneficial in mammography, whereas it is not advantageous in tomosynthesis. Lastly, the results suggest that temporal subtraction in general outperforms dual-energy subtraction.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
Similar content being viewed by others
References
Kiarashi, N., Lin, Y., Segars, W.P., Ghate, S.V., Ikejimba, L., Chen, B., Lo, J.Y., Dobbins III, J.T., Nolte, L.W., Samei, E.: Development of a Dynamic 4D Anthropomorphic Breast Phantom for Contrast-based Breast Imaging. In: Proc. SPIE, vol. 8313, pp. 0C1–0C7 (2012)
Chen, B., Shorey, J., Saunders, R.S., Richard, S., Thompson, J., Nolte, L.W., Samei, E.: An anthropomorphic breast model for breast imaging simulation and optimization. Acad. Radiol. 18(5), 536–546 (2011)
Li, C.M., Segars, W.P., Lo, J.Y., Dobbins III, J.T., Veress, A.I., Boone, J.M.: Three-dimensional computer generated breast phantom based on empirical data. In: Proc. SPIE, vol. 6913, pp. 14.1–14.8 (2008)
Li, C.M., Segars, W.P., Dobbins III, J.T., Tourassi, G.D., Boone, J.M.: Methodology for generating a 3D computerized breast phantom from empirical data. Med. Phys. 36(7), 3122–3131 (2009)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2012 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Kiarashi, N., Ghate, S.V., Lo, J.Y., Nolte, L.W., Samei, E. (2012). Application of a Dynamic 4D Anthropomorphic Breast Phantom in Contrast-Based Imaging System Optimization: Dual-Energy or Temporal Subtraction?. In: Maidment, A.D.A., Bakic, P.R., Gavenonis, S. (eds) Breast Imaging. IWDM 2012. Lecture Notes in Computer Science, vol 7361. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-31271-7_85
Download citation
DOI: https://doi.org/10.1007/978-3-642-31271-7_85
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-31270-0
Online ISBN: 978-3-642-31271-7
eBook Packages: Computer ScienceComputer Science (R0)