Abstract
This work presents simulation, analysis and experimental verification of Fast Fourier Transform (FFT) algorithm for shunt active power filter based on three-level inverter. Different types of filters can be used for elimination of harmonics in the power system. In this work, FFT algorithm for reference current generation is discussed. FFT control algorithm is verified using PSIM simulation results with DLL block and C-code. Simulation results are compared with experimental results for FFT algorithm using DSP TMS320F28335 for shunt active power filter application.
Similar content being viewed by others
References
J. Rodriguez, J.-S. Lai, F.Z. Peng, Multilevel inverters: a survey of topologies, controls, and applications. IEEE Trans. Ind. Electron. 49(4), 724–738 (2002)
M. Schneider, L. Moran, J. Dixon, An active power filter implemented with a three-level NPC voltage-source inverter. in 28th Annual IEEE Power Electronics Specialists Conference (PESC’97), vol. 2, pp. 1121–1126, 22–27 October 1997
S. Hui, Z. Ji-yan, L. Wei-dong, A novel active power filter using multilevel converter with self voltage balancing. in IEEE Proceedings of International Conference on Power System Technology (Power Con 2002), vol 4, pp. 2275–2279, 13–17 October 2002
B. Wu, High-Power Converters and AC Drives (IEEE Press and Wiley, New York, 2006), pp. 143–176
O. Vodyakho, T. Kim, S. Kwak, C.S. Edrington, Comparison of the space vector current controls for shunt active power filters. IET Power Electron. 2(6), 653–664 (2009)
J.W. Cooley, J.W. Tukey, An algorithm for the machine calculation of complex Fourier series. Math. Comput. 19, 297–301 (1965)
S.D. Round, D.M.E. Ingram, An evaluation of techniques for determining active filter compensating currents in unbalanced systems. Proc. EPE Trondheim 4, 767–772 (1997)
L. Asiminoaei, F. Blaabjerg, S. Hansen, Evaluation of harmonic detection methods for active power filter applications. in Twentieth Annual IEEE Applied Power Electronics Conference and Exposition, APEC 2005, vol 1, pp. 635–641, 2005
S. Mariethoz, A. Rufer, Open and closed-loop spectral frequency filtering. IEEE Trans. Power Electron. 17, 564–573 (2002)
J.A. Patel, Design Analysis and Implementation of Shunt Active Filter Based on Selective Harmonic Elimination Technique and p-q Theory for Power Quality Improvement. M.Tech. Thesis, Nirma University, May 2007
M. Mohseni, S.M. Islam, A new vector-based hysteresis current control scheme for three-phase PWM voltage-source inverters. IEEE Trans. Power Syst. 25(9), 2299–2309 (2010)
P.J. Patel, V. Patel, P.N. Tekwani, Pulse-based dead-time compensation method for self-balancing space vector pulse width-modulated scheme used in three-level inverter-fed induction motor drive. IET Res. J. Power Electron. 4(6), 624–631 (2011)
M.P. Kazmierkowski, M.A. Dzieniakowski, W. Sulkowski, Novel space vector based current controllers for PWM-inverters. IEEE Trans. Power Electron. 6(1), 158–166 (1991)
B. Singh, K. Al-Haddad, A. Chandra, A new control approach to three phase active filter for harmonics and reactive power compensation. IEEE Trans. Power Syst. 13(1), 133–138 (1998)
M. Suresh, S.S. Patnaik, Y. Suresh, A.K. Panda, Comparison of Two Compensation Control Strategies for Shunt Active Power Filter in Three-Phase Four-Wire System, Innovative Smart Grid Technologies (ISGT), (IEEE PES, Hilton Anaheim, CA, 2011), pp. 1–6
L. Asiminoaei, F. Blaabjerg, S. Hansen, Evaluation of harmonic detection methods for active power filter applications. Proc. IEEE Int. Conf. 1, 635–641 (2005)
TMS320F28335 Digital Signal Controllers, Data Manual, Literature Number: SPRS439H by Texas Instrument, Revised March 2010
Acknowledgements
This work is supported by Rural and Development Centre, Amtech Electronics (I) Ltd., Gandhinagar, Gujarat, India.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Patel, P.J., Patel, R.M. & Patel, V. Implementation of FFT Algorithm using DSP TMS320F28335 for Shunt Active Power Filter. J. Inst. Eng. India Ser. B 98, 321–327 (2017). https://doi.org/10.1007/s40031-016-0258-0
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s40031-016-0258-0