Abstract
The pocket ultrasound device (PUD) is a new tool that may be of use in the early detection of ascites. Abdominal ultrasound-guided paracentesis has been reported to decrease the rate of complications due to the procedure, but must be performed in a healthcare setting; this new tool may be a useful on an ambulatory basis. The aim of this study was to determine the diagnostic usefulness of the PUD in the diagnosis of ascites and the safety of guided paracentesis. We conducted a retrospective study that included adult patients suspected of having ascites and in whom an evaluation was performed with the PUD to identify it. Concordance with abdominal ultrasound (AUS) was determined with the Kappa coefficient. Sensitivity (Se), specificity (Sp) and likelihood ratios (LR) were determined and compared with physical examination, AUS, computed tomography and procurement of fluid by paracentesis. Complications resulting from the guided paracentesis were analyzed. 89 participants were included and 40 underwent a paracentesis. The PUD for ascites detection had 95.8 % Se, 81.8 % Sp, 5.27 +LR and 0.05 −LR. It had a concordance with AUS of 0.781 (p < 0.001). Technical problems during the guided paracentesis were present in only two participants (5 %) and three patients (7.5 %) developed minor complications that required no further intervention. There were no severe complications or deaths. This study suggests that the PUD is a reliable tool for ascites detection as a complement to physical examination and appears to be a safe method to perform guided paracentesis.

Similar content being viewed by others
References
Ginès P, Angeli P, Lenz K, Møller S, Moore K, Moreau R et al (2010) EASL clinical practice guidelines on the management of ascities, spontaneous bacterial peritonitis, and hepatorenal síndrome in cirrosis. J Hepatol 53:397–417
Goldberg BB, Clearfield HR, Goodman GA, Morales JO (1973) Ultrasonic determination of ascites. Arch Intern Med 131(2):217–220
Cattau EL Jr, Benjamin SB, Knuff TE, Castell DO (1982) The accuracy of the physical exam in the diagnosis of suspected ascites. JAMA 247:1164–1166
Chongtham DS, Singh MM, Kalantri SP, Pathak S, Jain AP (1998) Accuracy of clinical manoeuvres in detection of minimal ascites. Indian J Med Sci 52(11):514–520
Branney SW, Wolfe RE, Moore EE, Albert NP, Heinig M, Mestek M et al (1995) Quantitative sensitivity of ultrasound in detecting free intraperitoneal fluid. J Trauma 39(2):375–380
Sakai H, Sheer TA, Mendler MH, Runyon BA (2005) Choosing the location for non-image guided abdominal paracentesis. Liver Int 25:984–986
Williams JW, Simel DL (2009) Chapter 6. Does this patient have ascities? How to divine fluid in the abdomen. In: Simel DL, Rennie D, Keitz SA (eds) The rational clinical examination: evidence-based clinical diagnosis. McGraw-Hill, New York, pp 65–73
Goldberg BB, Goodman GA, Clearfield HR (1970) Evaluation of ascites by ultrasound. Radiology 96(1):15–22
Runyon BA (1986) Paracentesis of ascitic fluid: a safe procedure. Arch Intern Med 146:2259–2261
Nazeer SR, Dewbre H, Miller AH (2005) Ultrasound-assisted paracentesis performed by emergency physicians vs the traditional technique. Am J Emerg Med 23(3):363–367
Lin CH, Shih FY, Ma MH, Chiang WC, Yang CW, Ko PC (2005) Should bleeding tendency deter abdominal paracentesis? Dig Liver Dis 37:946–951
Ross GJ, Kessler HB, Clair MR, Gatenby RA, Hartz WH, Ross LV (1989) Sonographically guided paracentesis for palliation of symptomatic malignant ascites. Am J Roentgenol 153:1309–1311
Bard C, Lafortune M, Breton G (1986) Ascites: ultrasound guidance or blind paracentesis? Can Med Assoc J 135:209–210
McGahan JP, Anderson MW, Walter JP (1986) Portable real-time sonographic and needle guidance systems for aspiration and drainage. Am J Roentgenol 147:1241–1246
Alcaraz FA, Juhl-Olsen P, Sloth E (2012) Advances in imaging: ultrasound in every physician´s pocket. Expert Opin Med Diagn 6(3):167–170
Lisi M, Cameli M, Mondillo S, Luzzi L, Zacà V, Cameli P et al (2012) Incremental value of pocket-sized imaging device for bedside diagnosis of unilateral pleural effusions and ultrasound guided thoracocentesis. Interact CardioVasc Thorac Surg 15:596–602
Mjolstad OC, Dalen H, Graven T, Kleinau JO, Salvesen O, Haugen BO (2012) Routinely adding ultrasound examinations by pocket-sized ultrasound devices improves inpatient diagnostics in a medical department. Eur J Intern Med 23:185–191
Biais M, Carrie C, Delaunay F, Morel N, Revel P, Janvier G (2012) Evaluation of a new pocket echoscopic device for focused cardiac utlrasonography in an emergency setting. Crit Care 16:R82
Galderisi M, Santoro A, Versiero M, Lomoriello VS, Esposito R, Raia R et al (2010) Improved cardiovascular diagnostic accuracy by pocket size imaging device in non-cardiologic outpatients: the NaUSiCa (Naples Ultrasound Stethoscope in Cardiology) study. Cardiovasc Ultrasound 8:51
Sayasneh A, Preisler J, Smith A, Saso S, Naji O, Abdallah Y et al (2012) Do pocket-sized ultrasound machines have the potential to be used as a tool to triage patients in obstetrics an gynecology? Ultrasound Obstet Gynecol 40:145–150
Barreiros AP, Cui XW, Ignee A, De Molo C, Pirri C, Dietrich CF (2014) EchoSchopy in scanning abdominal disease: initial clinical experience. Z Gastroentrol 52:269–275
Colli A, Prati D, Fraquelli M, Segato S, Vescovi PP, Colombo F et al (2015) The use of a pocket sized ultrasound device improves physical examination: results of an in- and outpatient cohort study. PLoS One 10(3):e0122181. doi:10.1371/journal.pone.0122181
Stock KF, Klein B, Steubl D, Lersch C, Heemann U, Wagenpfeil S et al (2015) Comparison of a pocket-size ultrasound device with a premium ultrasound machine: diagnostic value and time required in bedside ultrasound examination. Abdom Imaging 40:2861–2866
De Gottardi A, Thévenot T, Spahr L, Morard I, Bresson-Hadni S, Torres F et al (2009) Risk of complications after abdominal paracentesis in cirrhotic patients: a prospective study. Clin Gastroenterol Hepatol 7:906–909
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
None.
Statement of human and animal rights
This paper is based upon a retrospective analysis. No impact or alteration in patient management was involved. Internal Review Board reviewed and approved this study as a retrospective analysis.
Informed consent
Patients signed informed consent for the procedure.
Rights and permissions
About this article
Cite this article
Keil-Ríos, D., Terrazas-Solís, H., González-Garay, A. et al. Pocket ultrasound device as a complement to physical examination for ascites evaluation and guided paracentesis. Intern Emerg Med 11, 461–466 (2016). https://doi.org/10.1007/s11739-016-1406-x
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11739-016-1406-x