Measuring skin conductance over clothes | Medical & Biological Engineering & Computing Skip to main content
Log in

Measuring skin conductance over clothes

  • Special Issue - Original Article
  • Published:
Medical & Biological Engineering & Computing Aims and scope Submit manuscript

Abstract

We propose a new method that measures skin conductance over clothes to nonintrusively monitor the changes in physiological conditions affecting skin conductance during daily activities. We selected the thigh-to-thigh current path and used an indirectly coupled 5-kHz AC current for the measurement. While varying the skin conductance by the Valsalva maneuver method, the results were compared with the traditional galvanic skin response (GSR) measured directly from the fingers. Skin conductance measured using a 5-kHz current displayed a highly negative correlation with the traditional GSR and the current measured over clothes reflected the rate of change of the conductance of the skin beneath.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Subscribe and save

Springer+ Basic
¥17,985 /Month
  • Get 10 units per month
  • Download Article/Chapter or eBook
  • 1 Unit = 1 Article or 1 Chapter
  • Cancel anytime
Subscribe now

Buy Now

Price includes VAT (Japan)

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

References

  1. Grimnes S (1982) Psychogalvanic reflex and changes in electrical parameters of dry skin. Med Biol Eng Comput 20:734–740

    Article  PubMed  CAS  Google Scholar 

  2. Gulbandilar E, Gulhan H (2010) A new measurement method for determination of low back pain. Sci Res Essays 5(22):3371–3377

    Google Scholar 

  3. Hong KH et al (2009) Effectiveness of thigh-to-thigh current path for the measurement of abdominal fat in bioelectrical impedance analysis. Med Biol Eng Comput 47:1265–1271

    Article  PubMed  Google Scholar 

  4. Lim YG et al (2006) ECG measurement on a chair without conductive contact. IEEE Trans Biomed Eng 53(5):956–959

    Article  PubMed  Google Scholar 

  5. Lloyd DPC (1960) Electrical impedance changes of the cat’s foot pad in relation to sweat secretion and reabsorption. J Gen Physiol 43:713–722

    Article  PubMed  CAS  Google Scholar 

  6. Lykken DT, Venables PH (1971) Direct measurement of skin conductance: a proposal for standardization. Psychophysiology 8(5):656–672

    Article  PubMed  CAS  Google Scholar 

  7. Sato K, Dobson RL (1970) Regional and individual variations in the function of the human eccrine sweat gland. J Invest Dermatol 54:443–449

    Article  PubMed  CAS  Google Scholar 

  8. Verchese A (1968) Some observations on the psychogalvanic reflex. Br J Psychiatry 114:639–642

    Article  Google Scholar 

Download references

Acknowledgments

This research was supported in part by the Public Welfare & Safety research program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education, Science and Technology (No. 2010-0020807) and in part by Seoul R&BD Program (JP090968M0209721).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Kwang Suk Park.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Hong, K.H., Lee, S.M., Lim, Y.G. et al. Measuring skin conductance over clothes. Med Biol Eng Comput 50, 1155–1161 (2012). https://doi.org/10.1007/s11517-012-0926-4

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11517-012-0926-4

Keywords

Navigation