Abstract
There is evidence that appropriate footwear is an important factor in the prevention of foot pain in otherwise healthy people or foot ulcers in people with diabetes and peripheral neuropathy. A standard care for reducing forefoot plantar pressure is the utilization of orthotic devices such as total contact inserts (TCI) with therapeutic footwear. Most neuropathic ulcers occur under the metatarsal heads, and foot deformity combined with high localized plantar pressure, appear to be the most significant factors contributing to these ulcers. In this study, patient-specific finite element models of the second ray of the foot were developed to study the influence of TCI design on peak plantar pressure (PPP) under the metatarsal heads. A typical full contact insert was modified based on the results of finite element analyses, by inserting 4 mm diameter cylindrical plugs of softer material in the regions of high pressure. Validation of the numerical model was addressed by comparing the numerical results obtained by the finite element method with measured pressure distribution in the region of the metatarsal heads for a shoe and TCI condition. Two subjects, one with a history of forefoot pain and one with diabetes and peripheral neuropathy, were tested in the laboratory while wearing therapeutic shoes and customized inserts. The study showed that customized inserts with softer plugs distributed throughout the regions of high plantar pressure reduced the PPP over that of the TCI alone. This supports the outcome as predicted by the numerical model, without causing edge effects as reported by other investigators using different plug designs, and provides a greater degree of flexibility for customizing orthotic devices than current practice allows.
Similar content being viewed by others
Abbreviations
- CT:
-
Computed tomography
- DM:
-
Diabetes mellitus
- FEA:
-
Finite element analysis
- SXCT:
-
Spiral X-ray computed tomography
- TCI:
-
Total contact insert
- PPP:
-
Peak plantar pressure
References
Actis RL, Ventura LB, Smith KE, Commean PK, Lott DJ, Pilgram TK, Mueller MJ (2006) Numerical simulation of the plantar pressure distribution in the diabetic foot during the push-off stance. Med Biol Eng Comput 44:653–663
Ashry HR, Lavery LA, Murdoch DP, Frolich M, Lavery DC (1997) Effectiveness of diabetic insoles to reduce foot pressures. J Foot Ankle Surg 36:268–271
Bus SA, Ulbrecht JS, Cavanagh PR (2004) Pressure relief and load redistribution by custom-made insoles in diabetic patients with neuropathy and foot deformity. Clin Biomech 19(6):629–638
Chantelau E, Haage P (1994) An audit of cushioned diabetic footwear: relation to patient compliance. Diabet Med 11(1):114–116
Chen WP, Ju CW, Tang F (2003) Effects of total contact insoles on the plantar stress distribution: a finite element analysis. Clin Biomech 18:S17–S24
Cheung JTM, Phil M, Zhang M (2005) A three-dimensional finite element model of the human foot and ankle for insole design. Arch Phys Med Rehabil 88:353–358
Commean PK, Mueller MJ, Smith KE, Hastings M, Klaesner J, Pilgram T, Robertson DD (2002) Reliability and validity for combined imaging and pressure assessment methods for diabetic feet. Arch Phys Med Rehabil 83(4):497–505
Edmonds M., Blundell M., Morris M et al (1986) Improved survival of the diabetic foot: the role of a specialized foot clinic. Q J Med 60(232):763–771
Erdemir A, Saucerman JJ, Lemmon D, Loppnow B, Turso B, Ulbretch J S, Cavanagh PR (2005) Local pressure relief in therapeutic footwear: design guidelines from finite element models. J Biomech 38:1798–1806
Gefen A (2003) Plantar soft tissue loading under the medial metatarsals in the standing diabetic foot. Med Eng Phys 25:491–499
Gefen A (2003) The in vivo elastic properties of the plantar Fascia during the contact phase of walking. Foot Ankle Int 24:238–244
Gefen A, Megido-Ravid M, Itzchak Y, Arcan M (2000) Biomechanical analysis of the three-dimensional foot structure during Gait: a basic tool for clinical applications. J Biomech Eng 122:630–639
Goske S, Erdemir A, Petre M, Budhabhatti S, Cavanagh PR (2005) Reduction of plantar heel pressure: insole design using finite element analysis. J Biomech 39:2363–2370
Hastings MK, Commean PK, Smith KE, Pilgram TK, Mueller MJ (2003) Aligning anatomical structure from spiral X-ray computed tomography with plantar pressure data. Clin Biomech 18:877–882
Jacob S, Patil MK (1999) Stress analysis in three-dimensional foot models of normal and diabetic Neuropathy. Front Med Biol Eng 9:211–227
Jacob S, Patil MK (1999) Three-dimensional foot modeling and analysis of stresses in normal and early stage Hansen’s disease with muscle paralysis. J Rehabil Res Dev 36:252–263
Lemmon D, Shiang TY, Hashmi A, Ulbrecht JS, Cavanagh PR (1997) The effect of insoles in therapeutic footwear––A finite element approach. J Biomech 30(6):615–620
Lord M, Hosein R (1994) Pressure redistribution by molded inserts in diabetic footwear: a pilot study. J Rehabil Res Dev 31(3):214–221
Mueller MJ, Strube MJ (1996) Generalizability of in-shoe peak pressure measures using the f-scan system. Clin Biomech 11:159–164
Mueller MJ, Lott DJ, Hastings MK, Commean PK, Smith KE, Pilgram HK (2006) Efficacy and mechanism of orthotic devices to unload metatarsal heads in people with diabetes and a history of plantar ulcers. Phys Ther 86(6):833–842
Nicolopoulos CS, Anderson EG, Solomonidis SE, Giannoudis PV (2000) Evaluation of the gait analysis FSCAN pressure system: clinical tool or toy? Foot 10:124–130
Pecoraro RE, Reiber GE, Burgess EM (1990) Pathways to diabetic limb amputation. Basis for prevention. Diabetes Care 13(5):513–521
Pitei DL, Lord M, Foster A, Wilson S, Watkins PJ, Edmonds ME (1999) Plantar pressures are elevated in the neuroischemic and the neuropathic diabetic foot. Diabetes Care 22(12):1966–1970
Robb RA, Barillot C (1989) Interactive display and analysis of 3-D medical images. IEEE Trans Med Imaging 8(3):217–226
Szabo BA, Babuska I (1991) Finite element analysis. Wiley, New York
Tsung BYS, Zhang M, Mak AFT, Wong MWN (2004) Effectiveness of insoles on plantar pressure redistribution. J Rehabil Res Dev 41(6A):767–774
Yamada H (1970) Strength of Biological Materials. The William & Wilkins Company, Baltimore
Acknowledgments
We acknowledge funding from NCMRR, NIH, RO1 HD 36895. We also acknowledge Mike Dailey, CPed CO, for fabricating orthotic devices used in this study.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Actis, R.L., Ventura, L.B., Lott, D.J. et al. Multi-plug insole design to reduce peak plantar pressure on the diabetic foot during walking. Med Biol Eng Comput 46, 363–371 (2008). https://doi.org/10.1007/s11517-008-0311-5
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11517-008-0311-5