Sliding-band dynamic range compression for use in hearing aids | International Journal of Speech Technology Skip to main content
Log in

Sliding-band dynamic range compression for use in hearing aids

  • Published:
International Journal of Speech Technology Aims and scope Submit manuscript

Abstract

Sensorineural hearing loss is associated with elevated hearing thresholds, reduced dynamic range, and loudness recruitment. Signal processing with dynamic range compression is used in hearing aids for presenting all the sounds comfortably within the limited dynamic range of the listener. A dynamic range compression technique, named as ‘sliding-band compression’, is proposed to overcome the shortcomings of the commonly used single-band and multiband compression techniques. The gain at each frequency index is calculated as a function of the short-time power in an auditory critical band centered at it. The technique avoids the attenuation of high-frequency components due to the presence of strong low-frequency components, which may occur in single-band compression. Further, it avoids distortions in the shape of spectral resonances and discontinuities during the resonance transitions, which may occur in multiband compression. The proposed technique was implemented for offline processing and compared with single-band compression and multiband compression using objective measures and different test inputs. For two-tone inputs, the single-band compression showed attenuation of the high-frequency tone with an increase in the level of the low-frequency tone. For swept-frequency single-tone input, the multiband compression showed errors in the tone amplitude of 1.5–2.5 dB for compression ratio of 2–10. Sliding-band compression did not show either type of error. The technique has been also implemented using a fixed-point processor for real-time processing with audio latency acceptable for face-to-face communication.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Subscribe and save

Springer+ Basic
¥17,985 /Month
  • Get 10 units per month
  • Download Article/Chapter or eBook
  • 1 Unit = 1 Article or 1 Chapter
  • Cancel anytime
Subscribe now

Buy Now

Price includes VAT (Japan)

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12

Similar content being viewed by others

Explore related subjects

Discover the latest articles, news and stories from top researchers in related subjects.

References

Download references

Funding

The funding was provided by Ministry of Electronics & Information Technology, Government of India (Grant No. DeitY/R&DffDC/13(3)/2013)

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Prem C. Pandey.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Tiwari, N., Pandey, P.C. Sliding-band dynamic range compression for use in hearing aids. Int J Speech Technol 22, 911–926 (2019). https://doi.org/10.1007/s10772-019-09635-4

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10772-019-09635-4

Keywords

Navigation