Abstract
The correlation between retinal vessel structural changes and the progression of diseases such as diabetes, hypertension, and cardiovascular problems has been the subject of several large-scale clinical studies. However, detecting structural changes in retinal vessels in a sufficiently fast and accurate manner, in the face of interfering pathologies, is a challenging task. This significantly limits the application of these studies to clinical practice. Though monumental work has already been proposed to extract vessels in retinal images, they mostly lack necessary sensitivity to pick low-contrast vessels. This paper presents a couple of contrast-sensitive measures to boost the sensitivity of existing retinal vessel segmentation algorithms. Firstly, a contrast normalization procedure for the vascular structure is adapted to lift low-contrast vessels to make them at par in comparison with their high-contrast counterparts. The second measure is to apply a scale-normalized detector that captures vessels regardless of their sizes. Thirdly, a flood-filled reconstruction strategy is adopted to get binary output. The process needs initialization with properly located seeds, generated here by another contrast-sensitive detector called isophote curvature. The final sensitivity boosting measure is an adoption process of binary fusion of two entirely different binary outputs due to two different illumination correction mechanism employed in the earlier processing stages. This results in improving the noise removal capability while picking low-contrast vessels. The contrast-sensitive steps are validated on a publicly available database, which shows considerable promise in the strategy adopted in this research work.



















Similar content being viewed by others
References
Sun C, Wang JJ, Mackey DA, Wong TY (2009) Retinal vascular caliber: systemic, environmental, and genetic associations. Surv Ophthalmol 54:74–95
Soomro TA, Gao J, Khan MAU, Khan TM, Paul M (2016) Role of image contrast enhancement technique for ophthalmologist as diagnostic tool for diabetic retinopathy. In: 2016 International conference on digital image computing: techniques and applications (DICTA), pp 1–8
Soomro TA, Khan MAU, Gao J, Khan TM, Paul M (2017) Contrast normalization steps for increased sensitivity of a retinal image segmentation method. J Signal Image Video Process. doi:10.1007/s11760-017-1114-7
Saine PJ, Tyler ME (2002) Ophthalmic photography: retinal photography, angiography, and electronic imaging, 2nd edn. Butterworth-Heinemann, Boston
Cassin B, Solomon SAB (1996) Dictionary of eye terminology, 2nd edn. Triad Publishing Company, Gainesville, FL
Pakter HM, Ferlin E, Fuchs SC, Maestri MK, Moraes RS (2005) Measuring arteriolar-to- venous ratio in retinal photography of patients with hypertension: development and application of a new semi-automated method. Am J Hypertens 18:417–421
Soares JVB, Leandro JJG, Cesar Jr RM, Jelinek HF, Cree MJ (2006) Retinal vessel segmentation using the 2-D Gabor wavelet and supervised classification. IEEE Trans Med Imaging 25:1214–1222
Soomro TA, Gao J, Khan TM, Hani AFM, Khan MAU, Paul M (2017) Computerised approaches for the detection of diabetic retinopathy using retinal fundus images: a survey. J Pattern Anal Appl. doi:10.1007/s10044-017-0630-y
Khan MAU, Soomro TA, Khan TM, Bailey DG, Gao J, Mir N (2016) Automatic retinal vessel extraction algorithm based on contrast-sensitive schemes. In: 2016 International conference on image and vision computing New Zealand (IVCNZ), pp 1–5
Lindberg T (1990) Scale-spcae for discrete signals. PAMI 12:234–254
Zana F, Klein J (2001) Segmentation of vessel-like patterns using mathematical morphology and curvature evaluation. IEEE Trans Image Process 10(7):1010–1019
Chaudhuri S, Chatterjee S, Katz N (1989) Detection of blood vessels in retinal images using two-dimensional matched filters. IEEE Trans Med Imaging 8:263–269
Heneghana C, Flynna J, OKeefec M, Cahillc M (2002) Characterization of changes in blood vessel width and tortuosity in retinopathy of prematurity using image analysis. Med Image Anal 6:407–429
Mendonca AM, Campilho A (2006) Segmentation of retinal blood vessels by combining the detection of centerlines and morphological reconstruction. IEEE Trans Med Imaging 25:1200–1213
Yang Y, Huang S, Rao N (2008) An automatic hybrid method for retinal blood vessel extraction. Int J Appl Math Comput Sci 18(3):399–407
Sun K, Chen Z, Jiang S (2011) Morphological multiscale enhancement, fuzzy filter and watershed for vascular tree extraction in angiogram. J Med Syst 35(5):811–824
Fraz MM, Remagnino P, Hoppe A, Uyyanonvara B, Rudnicka AR, Owen CG, Barman SA (2012) An ensemble classification-based approach applied to retinal blood vessel segmentation. IEEE Trans Biomed Eng 59(9):2538–2548
Lalkhen AG, McCluske A (2008) Clinical tests: sensitivity and specificity. Contin Educ Anaesth 8(6):221–223
Kanan C, Cottrell GW (2012) Color-to-grayscale: does the method matter in image recognition? PLoS ONE 7:1–7
Staal J, Abramoff MD, Niemeijer M, Viergever MA, Ginneken BV (2004) Ridge based vessel segmentation in color images of the retina. IEEE Trans Med Imaging 23(4):501–509
Vincent L (1993) Morphological gray scale reconstruction in image analysis: applications and efficient algorithms. IEEE Trans Image Process 2(2):176–201
Haijun L, Lingmin L, Xianyi L (2010) A novel preprocessing approach for digital meter reading based on computer vision. In: Proceedings of the third international symposium on computer science and computational technology vol 1, pp 308–311
Dragut L, Eisank C, Strasser T (2011) Local variance for multi-scale analysis in geomorphometry. Geomorphology 130:162–172
Khan TM, Bailey DG, Khan MAU, Kong Y (2016) Efficient hardware implementation strategy for local normalization of fingerprint images. J Real-Time Image Process. doi:10.1007/s11554-016-0625-8
Gottschlich C, Schonlieb C-B (2012) Oriented diffusion filtering for enhancing low-quality fingerprint images. IET Biom 1:105–113
Khan TM, Khan MAU, Kong Y, Kittaneh O (2016) Stopping criterion for linear anisotropic image diffusion: a fingerprint image enhancement case. EURASIP J Image Video Process. doi:10.1186/s13640-016-0105-x
Valenti R, Gevers T (2008) Accurate eye center location and tracking using isophote curvature. In: IEEE Conference on computer vision and pattern recognition, pp 1–8
De Marcoa T, Cazzatoa D, Leoa M, Distantea C (2015) Randomized circle detection with isophotes curvature analysis. Pattern Recognit 48(2):411–421
Gonzalez Rafael C, Woods Richard E (2006) Digital image processing, 3rd edn. Prentice Hall, Upper Saddle River
Research Section. Digital retinal image for vessel extraction (drive) database. Utrecht, The Netherlands, Univ. Med. Center Utrecht, Image Sci. Inst. http://www.isi.uu.nl/Re-search/Databases/DRIVE
STARE Project. Website. clemson sc clemson univ. http://www.ces.clemson.edu/
Hoover A, Kouznetsova V, Goldbaum M (2000) Locating blood vessels in retinal images by piecewise threshold probing of a matched filter response. IEEE Trans Med Imaging 19(3):203210
Nguyen UTV, Bhuiyan A, Park LAF, Ramamohanarao K (2013) An effective retinal blood vessel segmentation method using multi-scale line detection. Pattern Recognit 46:703–715
Hou Y (2014) Automatic segmentation of retinal blood vessels based on improved multiscale line detection. J Comput Sci Eng 8(2):119–128
Soomro TA, Khan MAU, Gao J, Khan TM, Paul M, Mir N (2016) Automatic retinal vessel extraction algorithm. In: International conference on digital image computing: techniques and applications (DICTA), pp 1–8
Ignacio JI, Blaschko M (2014) Learning fully-connected CRFs for blood vessel segmentation in retinal images. Med Image Comput Comput Assist Interv (MICCAI) 17:634–641
Liskowski P, Krawiec K (2016) Segmenting retinal blood vessels with deep neural networks. IEEE Trans Med Imaging 35(11):2369–2380
Lupas CA, Tegolo D, Trucco E (2010) FABC: retinal vessel segmentation using AdaBoost. IEEE Trans Inf Technol Biomed 14(5):1267–1274
Martinez-Perez ME, Hughes AD, Thom SA (2007) Segmentation of blood vessels from red-free and fluorescein retinal images. J Med Image Anal 11(1):47–61
Miguel A, Palomera-Perez M, Martinez-Perez E, Benitez-Perez H, Ortega-Arjona JL (2010) Parallel multiscale feature extraction and region growing: application in retinal blood vessel detection. IEEE Trans Inf Technol Biomed 14(2):500–506
Yin X, Ng BW-H, He J, Zhang Y, Abbott D (2014) Accurate image analysis of the retina using hessian matrix and binarisation of thresholded entropy with application of texture mapping. PLoS ONE 9(4):1–17
Zhao Y, Rada L, Chen K, Harding SP, Zheng Y (2015) Automated vessel segmentation using infinite perimeter active contour model with hybrid region information with application to retinal images. IEEE Trans Med Imaging 34(9):1797–1807
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Khan, M.A.U., Khan, T.M., Soomro, T.A. et al. Boosting sensitivity of a retinal vessel segmentation algorithm. Pattern Anal Applic 22, 583–599 (2019). https://doi.org/10.1007/s10044-017-0661-4
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10044-017-0661-4