Zusammenfassung
Chemical exchange saturation transfer (CEST) is an MRI technique used to identify solute molecules through proton exchange. The CEST spectrum reveals various metabolite effects, which are extracted using Lorentzian curve fitting. However, the effectiveness of the separation of CEST effects is compromised by the inhomogeneity of the B1 saturation field and noise in the acquisition. These inconsistencies result in variations within the associated metabolic maps. The existing B1 correction methods necessitate a minimum of two sets of CEST spectra. From these, a B1-corrected CEST spectrum at a fixed B1 level is interpolated, effectively doubling the acquisition time. In this study, we investigated the use of an unsupervised physics-informed conditional autoencoder (PICAE) to efficiently correct B1 inhomogeneity and isolate metabolic maps while using a single CEST scan. The proposed method uses two autoencoders. Conditional autoencoder (CAE) for B1 correction of the CEST spectrum at arbitrary B1 levels and Physical Informed Autoencoder (PIAE) for Lorentzian line fitting. CAE consists of fully connected layers whose latent space and input are both conditioned at the B1 level, eliminating the need for a second scan. PIAE uses a fully connected neural network as an encoder and a Lorentzian distribution generator as a decoder. This not only facilitates model interpretation, but also overcomes the shortcomings of traditional curve fitting, in particular its susceptibility to noise. The PICAE-CEST maps showed improved visualization of tumor features compared to the conventional method. The proposed method yielded at least 25% higher structural similarity index (SSIM) compared to the T1-weighted reference image enhanced with the exogenous contrast agent gadolinium in the tumor ring region. In addition, the contrast maps exhibited lower noise and greater homogeneity throughout the brain compared to the Lorentzian fit of the interpolation-based B1-corrected CEST spectrum [1].
Chapter PDF
Similar content being viewed by others
References
Rajput JR, Möhle TA, Fabian MS, Mennecke A, Sembill JA, Kuramatsu JB et al. Physicsinformed conditional autoencoder approach for robust metabolic CEST MRI at 7T. Proc MICCAI. Springer, 2023:449–58.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2024 Der/die Autor(en), exklusiv lizenziert an Springer Fachmedien Wiesbaden GmbH, ein Teil von Springer Nature
About this paper
Cite this paper
Rajput, J.R. et al. (2024). Abstract: Physics-informed Conditional Autoencoder Approach for Robust Metabolic CEST MRI at 7T. In: Maier, A., Deserno, T.M., Handels, H., Maier-Hein, K., Palm, C., Tolxdorff, T. (eds) Bildverarbeitung für die Medizin 2024. BVM 2024. Informatik aktuell. Springer Vieweg, Wiesbaden. https://doi.org/10.1007/978-3-658-44037-4_87
Download citation
DOI: https://doi.org/10.1007/978-3-658-44037-4_87
Published:
Publisher Name: Springer Vieweg, Wiesbaden
Print ISBN: 978-3-658-44036-7
Online ISBN: 978-3-658-44037-4
eBook Packages: Computer Science and Engineering (German Language)