Abstract
A methodology for adjusting mammographic images taken on a given imaging system to simulate their appearance if taken on a different system for use in observer studies is presented. The process involves adjusting the image sharpness and noise, which takes into account the detector, breast thickness, and beam quality. The method has been tested by converting images acquired using an a-Se detector of a CDMAM test object and ‘Rachel’ anthropomorphic breast phantom. They were degraded to appear as if acquired using a computed radiography (CR) detector. Good agreement was achieved in the resulting threshold gold thickness for the simulated CR images with measured real values for CDMAM images. Power spectra comparisons of real and simulated images of the ‘Rachel’ phantom agree with an average difference of 4%. This tool in conjunction with observer studies can be used to understand the effects of the detector characteristics on cancer detection in mammography.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
Similar content being viewed by others
References
Mackenzie, A., Dance, D.R., Workman, A., Yip, M., Wells, K., Young, K.C.: Development and validation of a method for converting images to appear with noise and sharpness characteristics of a different detector and X-ray system. Med. Phys. 39, 2721–2734 (2012)
Boone, J.M., Fewell, T.R., Jennings, R.J.: Molybdenum, rhodium, and tungsten anode spectral models using interpolating polynomials with application to mammography. Med. Phys. 24, 1863–1874 (1997)
Berger, M.J., Hubbell, J.H., Seltzer, S.M., Chang, J., Coursey, J.S., et al.: XCOM: Photon cross sections database. NIST Standard Reference Database 8, 87-3597 (1998)
Dance, D.R., Skinner, C.L., Young, K.C., Beckett, J.R., Kotre, C.J.: Additional factors for the estimation of mean glandular breast dose using the UK mammography dosimetry protocol. Phys. Med. Biol. 45, 3225–3240 (2000)
Young, K.C., Alsager, A., Oduko, J.M., Bosmans, H., Verbrugge, B., et al.: Evaluation of software for reading images of the CDMAM test object to assess digital mammography systems. In: Proc. SPIE, vol. 6913, pp. 69131C-1–69131C-11 (2008)
Warren, L.M., Mackenzie, A., Cooke, J., Given-Wilson, R., Wallis, M.G., et al.: Mammographic calcification cluster detection and threshold gold thickness measurements. In: Proc. SPIE, vol. 8313, p. 83130J (2012)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2012 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Mackenzie, A., Dance, D.R., Diaz, O., Barnard, A., Young, K.C. (2012). Converting One Set of Mammograms to Simulate a Range of Detector Imaging Characteristics for Observer Studies. In: Maidment, A.D.A., Bakic, P.R., Gavenonis, S. (eds) Breast Imaging. IWDM 2012. Lecture Notes in Computer Science, vol 7361. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-31271-7_51
Download citation
DOI: https://doi.org/10.1007/978-3-642-31271-7_51
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-31270-0
Online ISBN: 978-3-642-31271-7
eBook Packages: Computer ScienceComputer Science (R0)