Abstract
Contrast-detail measurements were made at approximately weekly intervals for three months, for two full-field mammography systems with different types of detector. The measured threshold contrast values were found to be reasonably stable but with some random variation. The coefficient of variance was 8-10% for detail sizes 0.1 and 1.0mm, and 3-5% for detail sizes 0.25 and 0.5mm. The output of both X-ray sets was also monitored, and found to vary within ±1% of the mean. The variation in threshold contrast is likely to be mainly due to variation of noise in the CDMAM images. Care should be taken when setting baselines and acceptable limits, so that measured changes in threshold contrast that are of the order of ±10% of the mean are not wrongly interpreted as significant changes in performance of a digital mammography system.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
Similar content being viewed by others
References
European Commission (EC): European Guidelines for Quality Assurance in Breast Cancer Screening and Diagnosis, 4th edn. Office for Official Publications of the European Communities, Luxembourg (2006)
Young, K.C., Alsager, A., Oduko, J.M., Bosmans, H., Verbrugge, B., Geertse, T., Van Engen, R.: Evaluation of software for reading images of the CDMAM test object to assess digital mammography systems. In: Proceedings of SPIE Medical Imaging, 69131C, 1–11 (2008)
Young K.C., Cook J.J.H., Oduko J.M., Bosmans H.: Comparison of software and human observers in reading images of the CDMAM test object to assess digital mammography systems. In: Proceedings of SPIE Medical Imaging, vol. 614206, pp. 1–13 (2006)
Young, K.C., Cook, J.J.H., Oduko, J.M.: Automated and Human Determination of Threshold Contrast for Digital Mammography Systems. In: Astley, S.M., Brady, M., Rose, C., Zwiggelaar, R. (eds.) IWDM 2006. LNCS, vol. 4046, pp. 266–272. Springer, Heidelberg (2006)
Yang, C.-Y.J., Van Metter, R.: The variability of software scoring of the CDMAM phantom associated with a limited number of images. In: Proceedings of SPIE Medical Imaging, 65100C (2007)
Dance, D.R., Young, K.C., van Engen, R.E.: Further factors for the estimation of mean glandular dose using the United Kingdom, European and IAEA dosimetry protocols. Phys. Med. Biol. 54, 4361–4372 (2009)
Mackenzie, A., Dance, D.R., Workman, A., Yip, M., Wells, K., Young, K.C.: Development and validation of a method for converting images to appear with noise and sharpness characteristics of a different detector and X-ray system. Med. Phys. 39(5), 2721–2734 (2012)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2012 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Oduko, J.M., Young, K.C. (2012). Long-Term Stability of Image Quality Measurements for Two Digital Mammography Systems. In: Maidment, A.D.A., Bakic, P.R., Gavenonis, S. (eds) Breast Imaging. IWDM 2012. Lecture Notes in Computer Science, vol 7361. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-31271-7_28
Download citation
DOI: https://doi.org/10.1007/978-3-642-31271-7_28
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-31270-0
Online ISBN: 978-3-642-31271-7
eBook Packages: Computer ScienceComputer Science (R0)