Abstract
We report on the improvements of the design and characteristics of a single energy absorptiometry (SXA) method to quantify the volume of dense breast tissue from mammograms. The method consists of including a breast tissue equivalent phantom in the unused portion of the mammogram as a reference for breast composition. The phantom contains nine lead positioning markers which solve for the orientation of the paddle by a 3D reconstruction least square technique. The volumetric breast density was calculated by comparing image pixel values to the fat/fibroglandular references at the same thickness and using an elaborated calibration map. The breast density precision and accuracy were determined by multiple scans of a test phantom at different compression thicknesses and paddle-tilt angles. We also estimated the error contribution due to thickness and tilt angle variations.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
Similar content being viewed by others
References
Pawluczyk, O., Augustine, B.J., Yaffe, M.J., Rico, D., Yang, J., Mawdsley, G.E., Boyd, N.F.: A volumetric method for estimation of breast density on digitized screen-film mammograms. Med. Phys. 30(3), 352–364 (2003)
Diffey, J., Hufton, A., Astley, S.: A New Step-Wedge for the Volumetric Measurement of Mammographic Density. In: IWDM, Manchester, England, pp. 1–9 (2006)
Marias, K., Behrenbruch, C., Highnam, R., Parbhoo, S., Seifalian, A., Brady, M.: A mammographic image analysis method to detect and measure changes in breast density. Eur. J. Radiol. 52(3), 276–282 (2004)
van Engeland, S., Snoeren, P.R., Huisman, H., Boetes, C., Karssemeijer, N.: Volumetric breast density estimation from full-field digital mammograms. IEEE Trans. Med. Imaging 25(3), 273–282 (2006)
Kaufhold, J., Thomas, J.A., Eberhard, J.W., Galbo, C.E., Trotter, D.E.: A calibration approach to glandular tissue composition estimation in digital mammography. Med. Phys. 29(8), 1867–1880 (2002)
Shepherd, J.A., Herve, L., Landau, J., Fan, B., Kerlikowske, K., Cummings, S.R.: Novel use of Single X-Ray Absorptiometry for Measuring Breast Density. Technol. Cancer Res. Treat 4(2), 173–182 (2005)
Malkov, S., Wang, J., Kerlikowske, K., Cummings, S., Shepher, J.A.: Digital Mammography Method for the Quantitative Measure of Dense Breast Tissue Volume. Med. Phys. (in press)
Author information
Authors and Affiliations
Editor information
Rights and permissions
Copyright information
© 2008 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Malkov, S., Wang, J., Shepherd, J. (2008). Improvements to Single Energy Absorptiometry Method for Digital Mammography to Quantify Breast Tissue Density. In: Krupinski, E.A. (eds) Digital Mammography. IWDM 2008. Lecture Notes in Computer Science, vol 5116. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-70538-3_1
Download citation
DOI: https://doi.org/10.1007/978-3-540-70538-3_1
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-70537-6
Online ISBN: 978-3-540-70538-3
eBook Packages: Computer ScienceComputer Science (R0)