Abstract
Previous studies have compared the performance of human observers to the performance of human observers using CAD. Here we compare the performance of human observers to Hologic’s ImageChecker CAD system using a set of 162 images with simulated calcification clusters. The quality of the images was reduced to create four other image sets at different image qualities. These were analysed by the CAD system and the relevant information from the resulting DICOM structured reports was parsed. At the highest image quality level the figure of merit for the CAD was 0.82 and 0.84 for the humans. At the lowest image quality level the figure of merit for the CAD and humans were 0.62 and 0.55 respectively. At each image quality level there was no significant difference (p>0.05). The effect of changes in image quality on calcification detection was similar for human observers and the CAD system.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
Similar content being viewed by others
References
Fenton, J.J., Abraham, L., Taplin, S.H., Geller, B.M., Carney, P.A., D’Orsi, C., Elmore, J.G., Barlow, W.E.: Effectiveness of computer-aided detection in community mammography practice. Journal of the National Cancer Institute 103(15), 1152–1161 (2011)
Warren, L.M., Mackenzie, A., Cooke, J., Given-Wilson, R.M., Wallis, M.G., Chakraborty, D.P., Dance, D.R., Bosmans, H., Young, K.C.: Effect of image quality on calcification detection in digital mammography. Med. Phys. 39, 3202–3213 (2012)
Warren, L.M., Green, F.H., Shrestha, L., Mackenzie, A., Dance, D.R., Young, K.C.: Validation of simulation of calcifications for observer studies in digital mammography. Phys. Med. Biol. 58, N217–N228 (2013)
Mason, D.: SU-E-T-33: Pydicom: An Open Source DICOM Library. Medical Physics 38, 3493–3493 (2011)
Hunter, J.D.: Matplotlib: A 2D graphics environment. Computing in Science & Engineering 9, 90–95 (2007)
Chakraborty, D.P.: Analysis of location specific observer performance data: Validated extensions of the jackknife free-response (JAFROC) method. Academic Radiology 13, 1187–1193 (2006)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2014 Springer International Publishing Switzerland
About this paper
Cite this paper
Looney, P.T., Warren, L.M., Astley, S.M., Young, K.C. (2014). Comparison of Calcification Cluster Detection by CAD and Human Observers at Different Image Quality Levels. In: Fujita, H., Hara, T., Muramatsu, C. (eds) Breast Imaging. IWDM 2014. Lecture Notes in Computer Science, vol 8539. Springer, Cham. https://doi.org/10.1007/978-3-319-07887-8_89
Download citation
DOI: https://doi.org/10.1007/978-3-319-07887-8_89
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-07886-1
Online ISBN: 978-3-319-07887-8
eBook Packages: Computer ScienceComputer Science (R0)