{"id":"https://openalex.org/W2634454755","doi":"https://doi.org/10.2352/issn.2169-2629.2017.32.71","title":"Non-Contact Video Based Estimation of Pulse Transit Time using Quantitation Method of Hemoglobin Level","display_name":"Non-Contact Video Based Estimation of Pulse Transit Time using Quantitation Method of Hemoglobin Level","publication_year":2016,"publication_date":"2016-11-07","ids":{"openalex":"https://openalex.org/W2634454755","doi":"https://doi.org/10.2352/issn.2169-2629.2017.32.71","mag":"2634454755"},"language":"en","primary_location":{"is_oa":false,"landing_page_url":"https://doi.org/10.2352/issn.2169-2629.2017.32.71","pdf_url":null,"source":{"id":"https://openalex.org/S4210193667","display_name":"Color and Imaging Conference","issn_l":"2166-9635","issn":["2166-9635","2169-2629"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false},"type":"article","type_crossref":"journal-article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5020446871","display_name":"Munenori Fukunishi","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Munenori Fukunishi","raw_affiliation_strings":[],"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5083838841","display_name":"Taku Yonezawa","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Taku Yonezawa","raw_affiliation_strings":[],"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5026750802","display_name":"Genki Okada","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Genki Okada","raw_affiliation_strings":[],"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5102282901","display_name":"Kouki Kurita","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Kouki Kurita","raw_affiliation_strings":[],"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101445428","display_name":"Shoji Yamamoto","orcid":"https://orcid.org/0000-0003-2112-8612"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Shoji Yamamoto","raw_affiliation_strings":[],"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5109934226","display_name":"Norimichi Tsumura","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Norimichi Tsumura","raw_affiliation_strings":[],"affiliations":[]}],"institution_assertions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.135,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.347326,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":66,"max":73},"biblio":{"volume":"24","issue":"1","first_page":"71","last_page":"75"},"is_retracted":false,"is_paratext":false,"primary_topic":{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9635,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9635,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/sphygmomanometer","display_name":"Sphygmomanometer","score":0.91081506},{"id":"https://openalex.org/keywords/cuff","display_name":"Cuff","score":0.45767164}],"concepts":[{"id":"https://openalex.org/C2910533495","wikidata":"https://www.wikidata.org/wiki/Q503968","display_name":"Sphygmomanometer","level":3,"score":0.91081506},{"id":"https://openalex.org/C84393581","wikidata":"https://www.wikidata.org/wiki/Q82642","display_name":"Blood pressure","level":2,"score":0.5184878},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.51254964},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.48478502},{"id":"https://openalex.org/C2780017030","wikidata":"https://www.wikidata.org/wiki/Q368366","display_name":"Cuff","level":2,"score":0.45767164},{"id":"https://openalex.org/C2778917026","wikidata":"https://www.wikidata.org/wiki/Q43041","display_name":"Hemoglobin","level":2,"score":0.43021327},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.33067614},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.29000556},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.22279543},{"id":"https://openalex.org/C141071460","wikidata":"https://www.wikidata.org/wiki/Q40821","display_name":"Surgery","level":1,"score":0.15106544},{"id":"https://openalex.org/C126322002","wikidata":"https://www.wikidata.org/wiki/Q11180","display_name":"Internal medicine","level":1,"score":0.10710642}],"mesh":[],"locations_count":1,"locations":[{"is_oa":false,"landing_page_url":"https://doi.org/10.2352/issn.2169-2629.2017.32.71","pdf_url":null,"source":{"id":"https://openalex.org/S4210193667","display_name":"Color and Imaging Conference","issn_l":"2166-9635","issn":["2166-9635","2169-2629"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false}],"best_oa_location":null,"sustainable_development_goals":[],"grants":[],"datasets":[],"versions":[],"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W4253962643","https://openalex.org/W2998068014","https://openalex.org/W2892790456","https://openalex.org/W2376189393","https://openalex.org/W2334829404","https://openalex.org/W2165067857","https://openalex.org/W2154448673","https://openalex.org/W2100399546","https://openalex.org/W2073179141","https://openalex.org/W2057576136"],"abstract_inverted_index":{"Blood":[0],"pressure":[1,15,92],"is":[2,45,49],"usually":[3],"measured":[4,19,84],"with":[5,20,37,94],"a":[6,10],"contact":[7,43],"device":[8],"called":[9],"sphygmomanometer":[11,95],"cuff.":[12],"Recently":[13],"blood":[14,91],"can":[16],"be":[17],"easily":[18],"portable":[21],"devices":[22],"such":[23],"as":[24],"smart":[25],"watches":[26],"that":[27],"take":[28],"advantage":[29],"of":[30,33,40,51,67,77,106],"the":[31,38,52,74,86,90,104,107],"progress":[32],"mobile":[34,41],"technology.":[35],"Even":[36],"use":[39],"devices,":[42],"measurement":[44,93],"still":[46],"required,":[47],"which":[48,102],"one":[50],"biggest":[53],"limitations":[54],"for":[55],"monitoring.":[56],"In":[57],"this":[58],"paper,":[59],"we":[60],"propose":[61],"non-contact":[62],"video":[63],"based":[64,72],"estimation":[65],"method":[66,76,88],"pulse":[68],"transit":[69],"time":[70],"(PTT)":[71],"on":[73],"quantitation":[75],"hemoglobin":[78],"level.":[79],"The":[80],"correlation":[81],"between":[82,98],"PTT":[83],"by":[85],"proposed":[87,108],"and":[89],"cuff":[96],"was":[97],"-0.5792":[99],"to":[100],"-0.7801,":[101],"confirms":[103],"effectiveness":[105],"method.":[109]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2634454755","counts_by_year":[{"year":2019,"cited_by_count":1}],"updated_date":"2025-01-16T19:53:23.765673","created_date":"2017-06-30"}