{"id":"https://openalex.org/W4391695339","doi":"https://doi.org/10.1109/sii58957.2024.10417675","title":"Non-Contact Blood Pressure Estimation Using Wi-Fi Channel State Information","display_name":"Non-Contact Blood Pressure Estimation Using Wi-Fi Channel State Information","publication_year":2024,"publication_date":"2024-01-08","ids":{"openalex":"https://openalex.org/W4391695339","doi":"https://doi.org/10.1109/sii58957.2024.10417675"},"language":"en","primary_location":{"is_oa":false,"landing_page_url":"https://doi.org/10.1109/sii58957.2024.10417675","pdf_url":null,"source":{"id":"https://openalex.org/S4363605592","display_name":"2022 IEEE/SICE International Symposium on System Integration (SII)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_indexed_in_scopus":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false},"type":"article","type_crossref":"proceedings-article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5102615696","display_name":"Koya Negishi","orcid":null},"institutions":[{"id":"https://openalex.org/I96679780","display_name":"Chuo University","ror":"https://ror.org/03qvqb743","country_code":"JP","type":"funder","lineage":["https://openalex.org/I96679780"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Koya Negishi","raw_affiliation_strings":["Department of Electrical, Elec-tronic, and Communication Engineering, Chuo University, Bunkyoku, Tokyo, Japan"],"affiliations":[{"raw_affiliation_string":"Department of Electrical, Elec-tronic, and Communication Engineering, Chuo University, Bunkyoku, Tokyo, Japan","institution_ids":["https://openalex.org/I96679780"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5020226940","display_name":"Kazuya Tsubota","orcid":null},"institutions":[{"id":"https://openalex.org/I96679780","display_name":"Chuo University","ror":"https://ror.org/03qvqb743","country_code":"JP","type":"funder","lineage":["https://openalex.org/I96679780"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Kazuya Tsubota","raw_affiliation_strings":["Department of Electrical, Elec-tronic, and Communication Engineering, Chuo University, Bunkyoku, Tokyo, Japan"],"affiliations":[{"raw_affiliation_string":"Department of Electrical, Elec-tronic, and Communication Engineering, Chuo University, Bunkyoku, Tokyo, Japan","institution_ids":["https://openalex.org/I96679780"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5051681101","display_name":"Takashi Ohhira","orcid":"https://orcid.org/0000-0002-1192-5477"},"institutions":[{"id":"https://openalex.org/I96679780","display_name":"Chuo University","ror":"https://ror.org/03qvqb743","country_code":"JP","type":"funder","lineage":["https://openalex.org/I96679780"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Takashi Ohhira","raw_affiliation_strings":["Department of Electrical, Elec-tronic, and Communication Engineering, Chuo University, Bunkyoku, Tokyo, Japan"],"affiliations":[{"raw_affiliation_string":"Department of Electrical, Elec-tronic, and Communication Engineering, Chuo University, Bunkyoku, Tokyo, Japan","institution_ids":["https://openalex.org/I96679780"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5032342136","display_name":"Hideki Hashimoto","orcid":"https://orcid.org/0000-0002-3281-8400"},"institutions":[{"id":"https://openalex.org/I96679780","display_name":"Chuo University","ror":"https://ror.org/03qvqb743","country_code":"JP","type":"funder","lineage":["https://openalex.org/I96679780"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Hideki Hashimoto","raw_affiliation_strings":["Department of Electrical, Elec-tronic, and Communication Engineering, Chuo University, Bunkyoku, Tokyo, Japan"],"affiliations":[{"raw_affiliation_string":"Department of Electrical, Elec-tronic, and Communication Engineering, Chuo University, Bunkyoku, Tokyo, Japan","institution_ids":["https://openalex.org/I96679780"]}]}],"institution_assertions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":0,"max":77},"biblio":{"volume":null,"issue":null,"first_page":"893","last_page":"898"},"is_retracted":false,"is_paratext":false,"primary_topic":{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9993,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9993,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10326","display_name":"Indoor and Outdoor Localization Technologies","score":0.9904,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11932","display_name":"Wireless Body Area Networks","score":0.9695,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/sphygmomanometer","display_name":"Sphygmomanometer","score":0.81681764},{"id":"https://openalex.org/keywords/photoplethysmogram","display_name":"Photoplethysmogram","score":0.5778611},{"id":"https://openalex.org/keywords/pressure-measurement","display_name":"Pressure measurement","score":0.45911023},{"id":"https://openalex.org/keywords/channel-state-information","display_name":"Channel state information","score":0.42883316}],"concepts":[{"id":"https://openalex.org/C2910533495","wikidata":"https://www.wikidata.org/wiki/Q503968","display_name":"Sphygmomanometer","level":3,"score":0.81681764},{"id":"https://openalex.org/C84393581","wikidata":"https://www.wikidata.org/wiki/Q82642","display_name":"Blood pressure","level":2,"score":0.7370905},{"id":"https://openalex.org/C116390426","wikidata":"https://www.wikidata.org/wiki/Q7187885","display_name":"Photoplethysmogram","level":3,"score":0.5778611},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5411749},{"id":"https://openalex.org/C80264047","wikidata":"https://www.wikidata.org/wiki/Q7424019","display_name":"Pressure measurement","level":2,"score":0.45911023},{"id":"https://openalex.org/C148063708","wikidata":"https://www.wikidata.org/wiki/Q5072511","display_name":"Channel state information","level":3,"score":0.42883316},{"id":"https://openalex.org/C127162648","wikidata":"https://www.wikidata.org/wiki/Q16858953","display_name":"Channel (broadcasting)","level":2,"score":0.4101828},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.38216195},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.17808849},{"id":"https://openalex.org/C31972630","wikidata":"https://www.wikidata.org/wiki/Q844240","display_name":"Computer vision","level":1,"score":0.15087852},{"id":"https://openalex.org/C126322002","wikidata":"https://www.wikidata.org/wiki/Q11180","display_name":"Internal medicine","level":1,"score":0.13229027},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.12062195},{"id":"https://openalex.org/C555944384","wikidata":"https://www.wikidata.org/wiki/Q249","display_name":"Wireless","level":2,"score":0.0},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C106131492","wikidata":"https://www.wikidata.org/wiki/Q3072260","display_name":"Filter (signal processing)","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"is_oa":false,"landing_page_url":"https://doi.org/10.1109/sii58957.2024.10417675","pdf_url":null,"source":{"id":"https://openalex.org/S4363605592","display_name":"2022 IEEE/SICE International Symposium on System Integration (SII)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_indexed_in_scopus":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false}],"best_oa_location":null,"sustainable_development_goals":[],"grants":[],"datasets":[],"versions":[],"referenced_works_count":27,"referenced_works":["https://openalex.org/W1952982039","https://openalex.org/W2000982976","https://openalex.org/W2064081294","https://openalex.org/W2089695767","https://openalex.org/W2130444042","https://openalex.org/W2143228105","https://openalex.org/W2512233354","https://openalex.org/W2734845228","https://openalex.org/W2783801642","https://openalex.org/W2791489307","https://openalex.org/W2886208970","https://openalex.org/W2911964244","https://openalex.org/W2912373861","https://openalex.org/W2979968846","https://openalex.org/W3004465995","https://openalex.org/W3018493579","https://openalex.org/W3036843588","https://openalex.org/W3084684553","https://openalex.org/W3139974943","https://openalex.org/W3150529520","https://openalex.org/W3189167202","https://openalex.org/W3190903107","https://openalex.org/W3196215306","https://openalex.org/W3214153036","https://openalex.org/W4211129655","https://openalex.org/W4321020393","https://openalex.org/W4381232950"],"related_works":["https://openalex.org/W4253707656","https://openalex.org/W38805444","https://openalex.org/W3165418382","https://openalex.org/W3089926590","https://openalex.org/W3031957795","https://openalex.org/W2898902003","https://openalex.org/W2768794232","https://openalex.org/W2372989409","https://openalex.org/W2323836097","https://openalex.org/W120577641"],"abstract_inverted_index":{"Monitoring":[0],"blood":[1,25,43,54,102,119,137],"pressure":[2,26,44,55,103,120,138],"on":[3,59],"a":[4,14,40,52,141],"daily":[5],"basis":[6],"is":[7,13,47,70,104,145],"crucial":[8],"in":[9,17,86],"preventing":[10],"hypertension,":[11],"which":[12,35],"leading":[15],"factor":[16],"the":[18,30,90,114],"development":[19],"of":[20,32,72,126],"cardiovascular":[21],"diseases.":[22],"The":[23],"conventional":[24],"measurement":[27,45],"method":[28,46,57,116],"involves":[29],"use":[31],"cuff-type":[33],"sphygmomanometers,":[34],"can":[36,117],"be":[37,148],"uncomfortable;":[38],"therefore,":[39],"comfortable,":[41],"non-contact":[42,53,79,136],"warranted.":[48],"Therefore,":[49],"we":[50],"propose":[51],"estimation":[56,81,139],"based":[58],"channel":[60],"state":[61],"information":[62],"(CSI)":[63],"obtained":[64,98],"from":[65,99],"general-purpose":[66,142],"Wi-Fi":[67,143],"devices.":[68],"CSI":[69],"capable":[71],"multipath":[73],"detailed":[74],"identification,":[75],"and":[76,94,101],"many":[77],"CSI-based":[78],"biometric":[80],"methods":[82],"have":[83],"been":[84],"proposed":[85,91,115],"recent":[87],"years.":[88],"In":[89],"method,":[92],"respiration":[93],"heartbeat":[95],"signals":[96],"are":[97],"CSI,":[100],"estimated":[105],"using":[106,140],"random":[107],"forest":[108],"regression.":[109],"Experimental":[110],"results":[111],"indicate":[112],"that":[113],"estimate":[118],"with":[121],"an":[122],"average":[123],"absolute":[124],"error":[125],"less":[127],"than":[128],"5":[129],"mmHg":[130],"compared":[131],"to":[132,147],"sphygmomanometer":[133],"measurements.":[134],"Thus,":[135],"device":[144],"demonstrated":[146],"feasible.":[149]},"abstract_inverted_index_v3":null,"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W4391695339","counts_by_year":[],"updated_date":"2025-04-16T01:41:33.967145","created_date":"2024-02-10"}