{"id":"https://openalex.org/W4282565249","doi":"https://doi.org/10.1109/lascas53948.2022.9789076","title":"Near threshold pulse transit time processor for central blood pressure estimation","display_name":"Near threshold pulse transit time processor for central blood pressure estimation","publication_year":2022,"publication_date":"2022-03-01","ids":{"openalex":"https://openalex.org/W4282565249","doi":"https://doi.org/10.1109/lascas53948.2022.9789076"},"language":"en","primary_location":{"is_oa":false,"landing_page_url":"https://doi.org/10.1109/lascas53948.2022.9789076","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false},"type":"article","type_crossref":"proceedings-article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5080574206","display_name":"Francisco Veirano","orcid":"https://orcid.org/0000-0001-6721-1855"},"institutions":[{"id":"https://openalex.org/I180910786","display_name":"Universidad de la Rep\u00fablica","ror":"https://ror.org/030bbe882","country_code":"UY","type":"education","lineage":["https://openalex.org/I180910786"]}],"countries":["UY"],"is_corresponding":false,"raw_author_name":"Francisco Veirano","raw_affiliation_strings":["Universidad de la República,Facultad de Ingenieria,Montevideo,Uruguay"],"affiliations":[{"raw_affiliation_string":"Universidad de la República,Facultad de Ingenieria,Montevideo,Uruguay","institution_ids":["https://openalex.org/I180910786"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5080201068","display_name":"Pablo P\u00e9rez-Nicoli","orcid":"https://orcid.org/0000-0002-6325-8303"},"institutions":[{"id":"https://openalex.org/I180910786","display_name":"Universidad de la Rep\u00fablica","ror":"https://ror.org/030bbe882","country_code":"UY","type":"education","lineage":["https://openalex.org/I180910786"]}],"countries":["UY"],"is_corresponding":false,"raw_author_name":"Pablo Perez-Nicoli","raw_affiliation_strings":["Universidad de la República,Facultad de Ingenieria,Montevideo,Uruguay"],"affiliations":[{"raw_affiliation_string":"Universidad de la República,Facultad de Ingenieria,Montevideo,Uruguay","institution_ids":["https://openalex.org/I180910786"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5084399482","display_name":"Nicol\u00e1s Gammarano","orcid":"https://orcid.org/0000-0001-9693-2926"},"institutions":[{"id":"https://openalex.org/I180910786","display_name":"Universidad de la Rep\u00fablica","ror":"https://ror.org/030bbe882","country_code":"UY","type":"education","lineage":["https://openalex.org/I180910786"]}],"countries":["UY"],"is_corresponding":false,"raw_author_name":"Nicolas Gammarano","raw_affiliation_strings":["Universidad de la República,Facultad de Ingenieria,Montevideo,Uruguay"],"affiliations":[{"raw_affiliation_string":"Universidad de la República,Facultad de Ingenieria,Montevideo,Uruguay","institution_ids":["https://openalex.org/I180910786"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5090334653","display_name":"Germ\u00e1n Fierro","orcid":"https://orcid.org/0000-0002-9386-6799"},"institutions":[{"id":"https://openalex.org/I180910786","display_name":"Universidad de la Rep\u00fablica","ror":"https://ror.org/030bbe882","country_code":"UY","type":"education","lineage":["https://openalex.org/I180910786"]}],"countries":["UY"],"is_corresponding":false,"raw_author_name":"German Fierro","raw_affiliation_strings":["Universidad de la República,Facultad de Ingenieria,Montevideo,Uruguay"],"affiliations":[{"raw_affiliation_string":"Universidad de la República,Facultad de Ingenieria,Montevideo,Uruguay","institution_ids":["https://openalex.org/I180910786"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5101812769","display_name":"Fernando Silveira","orcid":"https://orcid.org/0000-0003-1205-8595"},"institutions":[{"id":"https://openalex.org/I180910786","display_name":"Universidad de la Rep\u00fablica","ror":"https://ror.org/030bbe882","country_code":"UY","type":"education","lineage":["https://openalex.org/I180910786"]}],"countries":["UY"],"is_corresponding":false,"raw_author_name":"Fernando Silveira","raw_affiliation_strings":["Universidad de la República,Facultad de Ingenieria,Montevideo,Uruguay"],"affiliations":[{"raw_affiliation_string":"Universidad de la República,Facultad de Ingenieria,Montevideo,Uruguay","institution_ids":["https://openalex.org/I180910786"]}]}],"institution_assertions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.118,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.345984,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":60,"max":70},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"4"},"is_retracted":false,"is_paratext":false,"primary_topic":{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11021","display_name":"ECG Monitoring and Analysis","score":0.9993,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T10745","display_name":"Heart Rate Variability and Autonomic Control","score":0.9987,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/transit-time","display_name":"Transit time","score":0.58127314}],"concepts":[{"id":"https://openalex.org/C3018129524","wikidata":"https://www.wikidata.org/wiki/Q7834377","display_name":"Transit time","level":2,"score":0.58127314},{"id":"https://openalex.org/C150594956","wikidata":"https://www.wikidata.org/wiki/Q1334829","display_name":"Wearable computer","level":2,"score":0.55843043},{"id":"https://openalex.org/C2780167933","wikidata":"https://www.wikidata.org/wiki/Q1550652","display_name":"Pulse (music)","level":3,"score":0.5569494},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.51914924},{"id":"https://openalex.org/C98045186","wikidata":"https://www.wikidata.org/wiki/Q205663","display_name":"Process (computing)","level":2,"score":0.4882896},{"id":"https://openalex.org/C92746544","wikidata":"https://www.wikidata.org/wiki/Q585184","display_name":"Pulse-width modulation","level":3,"score":0.48396376},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.45507917},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.4188745},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.39920032},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.3452801},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.27050528},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.26598996},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.1447066},{"id":"https://openalex.org/C22212356","wikidata":"https://www.wikidata.org/wiki/Q775325","display_name":"Transport engineering","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"is_oa":false,"landing_page_url":"https://doi.org/10.1109/lascas53948.2022.9789076","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false}],"best_oa_location":null,"sustainable_development_goals":[],"grants":[],"datasets":[],"versions":[],"referenced_works_count":10,"referenced_works":["https://openalex.org/W1980246793","https://openalex.org/W2048785750","https://openalex.org/W2294418644","https://openalex.org/W2327760204","https://openalex.org/W2533732668","https://openalex.org/W2894852283","https://openalex.org/W2948321969","https://openalex.org/W3011870228","https://openalex.org/W3117330818","https://openalex.org/W3126348555"],"related_works":["https://openalex.org/W3204276839","https://openalex.org/W3181468185","https://openalex.org/W2902660993","https://openalex.org/W2763152318","https://openalex.org/W2294565841","https://openalex.org/W2187813406","https://openalex.org/W2137992531","https://openalex.org/W2040398333","https://openalex.org/W1878742981","https://openalex.org/W1501882840"],"abstract_inverted_index":{"In":[0],"this":[1,40],"work":[2],"a":[3,60],"digital":[4,116],"peripheral":[5,70],"that":[6,93],"can":[7,99],"measure":[8],"pulse":[9],"transit":[10],"time":[11,30,42],"for":[12,44,106],"central":[13,110],"blood":[14,111],"pressure":[15,112],"estimation":[16,108],"is":[17],"presented.":[18,68],"To":[19],"do":[20],"so,":[21],"it":[22],"processes":[23],"ECG":[24,37],"and":[25,38,53,64,76],"BCG":[26],"signals":[27],"in":[28,35,59,102,118],"real":[29],"by":[31],"detecting":[32],"the":[33,36,73,96,103,115,119],"R-waves":[34],"using":[39],"as":[41,50],"reference":[43],"measuring":[45],"intervals":[46],"of":[47,83,95,109],"interest":[48],"such":[49],"RJ,":[51],"IJ":[52],"RR.":[54],"The":[55,69],"circuit":[56,117],"was":[57],"fabricated":[58],"180":[61],"nm":[62],"process":[63],"experimental":[65],"results":[66],"are":[67],"works":[71],"at":[72,88],"near-threshold":[74,120],"region":[75],"consumes":[77],"7":[78],"pJ/cycle":[79],"with":[80],"0.43":[81],"V":[82],"supply":[84],"voltage":[85],"while":[86,113],"operating":[87,114],"8":[89],"kHz.":[90],"We":[91],"showed":[92],"state":[94],"art":[97],"performance":[98],"be":[100],"achieved":[101],"processing":[104],"required":[105],"wearable":[107],"region.":[121]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W4282565249","counts_by_year":[{"year":2022,"cited_by_count":1}],"updated_date":"2024-12-11T11:56:00.716995","created_date":"2022-06-14"}