{"id":"https://openalex.org/W2274465789","doi":"https://doi.org/10.1109/iecon.2015.7392253","title":"Case stories of advanced rotor assessment in field motors operated with soft-starters and frequency converters","display_name":"Case stories of advanced rotor assessment in field motors operated with soft-starters and frequency converters","publication_year":2015,"publication_date":"2015-11-01","ids":{"openalex":"https://openalex.org/W2274465789","doi":"https://doi.org/10.1109/iecon.2015.7392253","mag":"2274465789"},"language":"en","primary_location":{"is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon.2015.7392253","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false},"type":"preprint","type_crossref":"proceedings-article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5066633137","display_name":"Jose A. Antonino\u2010Daviu","orcid":"https://orcid.org/0000-0003-1898-2228"},"institutions":[{"id":"https://openalex.org/I60053951","display_name":"Universitat Polit\u00e8cnica de Val\u00e8ncia","ror":"https://ror.org/01460j859","country_code":"ES","type":"education","lineage":["https://openalex.org/I60053951"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"J. Antonino-Daviu","raw_affiliation_strings":["Universitat Polit\u00e8cnica de Val\u00e8ncia"],"affiliations":[{"raw_affiliation_string":"Universitat Polit\u00e8cnica de Val\u00e8ncia","institution_ids":["https://openalex.org/I60053951"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5001659474","display_name":"Jes\u00fas A. Corral-Hern\u00e1ndez","orcid":null},"institutions":[{"id":"https://openalex.org/I60053951","display_name":"Universitat Polit\u00e8cnica de Val\u00e8ncia","ror":"https://ror.org/01460j859","country_code":"ES","type":"education","lineage":["https://openalex.org/I60053951"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"J. Corral-Hernandez","raw_affiliation_strings":["Universitat Polit\u00e8cnica de Val\u00e8ncia"],"affiliations":[{"raw_affiliation_string":"Universitat Polit\u00e8cnica de Val\u00e8ncia","institution_ids":["https://openalex.org/I60053951"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5039686647","display_name":"Vicente Climente-Alarc\u00f3n","orcid":"https://orcid.org/0000-0002-1273-8454"},"institutions":[{"id":"https://openalex.org/I9927081","display_name":"Aalto University","ror":"https://ror.org/020hwjq30","country_code":"FI","type":"education","lineage":["https://openalex.org/I9927081"]}],"countries":["FI"],"is_corresponding":false,"raw_author_name":"Vicente Climente-Alarcon","raw_affiliation_strings":["Aalto University"],"affiliations":[{"raw_affiliation_string":"Aalto University","institution_ids":["https://openalex.org/I9927081"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5087840767","display_name":"Hubert Razik","orcid":"https://orcid.org/0000-0003-0192-4259"},"institutions":[{"id":"https://openalex.org/I4210145913","display_name":"Laboratoire Amp\u00e8re","ror":"https://ror.org/04xbczw40","country_code":"FR","type":"facility","lineage":["https://openalex.org/I100532134","https://openalex.org/I112936343","https://openalex.org/I1294671590","https://openalex.org/I203339264","https://openalex.org/I4210095849","https://openalex.org/I4210145913","https://openalex.org/I48430043"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"H. Razik","raw_affiliation_strings":["Amp\u00e8re, D\u00e9partement M\u00e9thodes pour l'Ing\u00e9nierie des Syst\u00e8mes"],"affiliations":[{"raw_affiliation_string":"Amp\u00e8re, D\u00e9partement M\u00e9thodes pour l'Ing\u00e9nierie des Syst\u00e8mes","institution_ids":["https://openalex.org/I4210145913"]}]}],"institution_assertions":[],"countries_distinct_count":3,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":true,"fulltext_origin":"ngrams","cited_by_count":7,"citation_normalized_percentile":{"value":0.840219,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":83,"max":84},"biblio":{"volume":null,"issue":null,"first_page":"001139","last_page":"001144"},"is_retracted":false,"is_paratext":false,"primary_topic":{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.9998,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.9998,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12169","display_name":"Non-Destructive Testing Techniques","score":0.9976,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13050","display_name":"Oil and Gas Production Techniques","score":0.9911,"subfield":{"id":"https://openalex.org/subfields/2212","display_name":"Ocean Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/wound-rotor-motor","display_name":"Wound rotor motor","score":0.6021011},{"id":"https://openalex.org/keywords/condition-monitoring","display_name":"Condition Monitoring","score":0.546177}],"concepts":[{"id":"https://openalex.org/C80962145","wikidata":"https://www.wikidata.org/wiki/Q207450","display_name":"Induction motor","level":3,"score":0.7730261},{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.74951875},{"id":"https://openalex.org/C17281054","wikidata":"https://www.wikidata.org/wiki/Q193466","display_name":"Rotor (electric)","level":2,"score":0.6824105},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.60248053},{"id":"https://openalex.org/C42672440","wikidata":"https://www.wikidata.org/wiki/Q643855","display_name":"Wound rotor motor","level":4,"score":0.6021011},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.5893132},{"id":"https://openalex.org/C2775846686","wikidata":"https://www.wikidata.org/wiki/Q643012","display_name":"Condition monitoring","level":2,"score":0.546177},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.45565888},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.4272819},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.4113554},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.34562752},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.32963467},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.23678294},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.16281214},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0872511},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.0},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.0}],"mesh":[],"locations_count":3,"locations":[{"is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon.2015.7392253","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false},{"is_oa":false,"landing_page_url":"https://hal.science/hal-01899876","pdf_url":null,"source":{"id":"https://openalex.org/S4306402512","display_name":"HAL (Le Centre pour la Communication Scientifique Directe)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1294671590","host_organization_name":"Centre National de la Recherche Scientifique","host_organization_lineage":["https://openalex.org/I1294671590"],"host_organization_lineage_names":["Centre National de la Recherche Scientifique"],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false},{"is_oa":false,"landing_page_url":"https://hal.archives-ouvertes.fr/hal-01899876","pdf_url":null,"source":{"id":"https://openalex.org/S4306402512","display_name":"HAL (Le Centre pour la Communication Scientifique Directe)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1294671590","host_organization_name":"Centre National de la Recherche Scientifique","host_organization_lineage":["https://openalex.org/I1294671590"],"host_organization_lineage_names":["Centre National de la Recherche Scientifique"],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/6","score":0.86,"display_name":"Clean water and sanitation"}],"grants":[],"datasets":[],"versions":[],"referenced_works_count":17,"referenced_works":["https://openalex.org/W2017400182","https://openalex.org/W2020452962","https://openalex.org/W2026550072","https://openalex.org/W2040683402","https://openalex.org/W2067451583","https://openalex.org/W2090203888","https://openalex.org/W2094623746","https://openalex.org/W2098027046","https://openalex.org/W2121552484","https://openalex.org/W2122024986","https://openalex.org/W2139783633","https://openalex.org/W2170547958","https://openalex.org/W2314783213","https://openalex.org/W2326987874","https://openalex.org/W2330970331","https://openalex.org/W2556725041","https://openalex.org/W4241838320"],"related_works":["https://openalex.org/W2902511954","https://openalex.org/W2786447778","https://openalex.org/W2768436007","https://openalex.org/W2548535020","https://openalex.org/W2532620819","https://openalex.org/W2187720790","https://openalex.org/W2036218083","https://openalex.org/W1980179937","https://openalex.org/W1950096351","https://openalex.org/W1878989367"],"abstract_inverted_index":{"Advanced":[0],"analysis":[1,119],"of":[2,11,30,40,48,61,102,120,129,166],"the":[3,12,18,24,28,38,46,59,99,103,117,121,164,167,170],"motor":[4,122],"starting":[5,123],"currents":[6],"enables":[7],"very":[8],"reliable":[9,100],"diagnostics":[10],"rotor":[13,62,77,104,171],"condition,":[14],"providing":[15],"immunity":[16],"against":[17],"eventual":[19],"false":[20],"alarms":[21],"obtained":[22,153],"with":[23,110,154],"conventional":[25],"MCSA.":[26],"However,":[27],"application":[29],"this":[31],"methodology":[32,168],"has":[33,53],"been":[34,54,88],"mainly":[35],"restricted":[36],"to":[37,45,66,76],"case":[39],"line-started":[41],"machines.":[42],"Its":[43],"extension":[44],"cases":[47,74],"soft-started":[49],"or":[50],"inverted-fed":[51],"motors":[52,81,108,156,175],"barely":[55],"investigated,":[56],"especially":[57],"because":[58],"probability":[60],"damage":[63],"is":[64],"claimed":[65],"be":[67],"reduced":[68],"under":[69],"such":[70,111],"conditions.":[71],"Nonetheless,":[72],"industrial":[73],"related":[75],"damages":[78],"in":[79,106,138,158,173],"induction":[80,107,174],"operated":[82,109,176],"via":[83,178],"soft-starters":[84,179],"and":[85,135,146,180],"frequency-converters":[86],"have":[87],"recently":[89],"reported.":[90],"This":[91],"paper":[92],"proposes":[93],"a":[94,159],"twofold":[95],"transient-based":[96],"approach":[97],"for":[98,169],"assessment":[101,172],"condition":[105],"elements.":[112],"The":[113],"method":[114],"relies":[115],"on":[116,133],"advanced":[118],"current":[124],"by":[125],"combining":[126],"two":[127,139],"types":[128],"time-frequency":[130],"approaches":[131],"(based":[132],"discrete":[134],"continuous":[136],"transforms)":[137],"subsequent":[140],"stages:":[141],"1)":[142],"fault":[143,148],"pattern":[144],"identification":[145],"2)":[147],"severity":[149],"quantification.":[150],"Field":[151],"results":[152],"large":[155],"operating":[157],"sewage":[160],"treatment":[161],"plant":[162],"confirm":[163],"validity":[165],"both":[177],"frequency":[181],"converters.":[182]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2274465789","counts_by_year":[{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":4},{"year":2019,"cited_by_count":1},{"year":2018,"cited_by_count":1}],"updated_date":"2025-01-07T01:43:12.746563","created_date":"2016-06-24"}