{"id":"https://openalex.org/W2889265207","doi":"https://doi.org/10.1109/icphm.2018.8448649","title":"Fault Isolation and Diagnosis of High Pressure Fuel Pump Solenoid Valves Using Current Feedback","display_name":"Fault Isolation and Diagnosis of High Pressure Fuel Pump Solenoid Valves Using Current Feedback","publication_year":2018,"publication_date":"2018-06-01","ids":{"openalex":"https://openalex.org/W2889265207","doi":"https://doi.org/10.1109/icphm.2018.8448649","mag":"2889265207"},"language":"en","primary_location":{"is_oa":false,"landing_page_url":"https://doi.org/10.1109/icphm.2018.8448649","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false},"type":"article","type_crossref":"proceedings-article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5055535539","display_name":"Azeem Sarwar","orcid":null},"institutions":[{"id":"https://openalex.org/I118136607","display_name":"General Motors (United States)","ror":"https://ror.org/05addee68","country_code":"US","type":"company","lineage":["https://openalex.org/I118136607"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Azeem Sarwar","raw_affiliation_strings":["Vehicle Health Management Group, General Motors Company, Warren, MI, USA"],"affiliations":[{"raw_affiliation_string":"Vehicle Health Management Group, General Motors Company, Warren, MI, USA","institution_ids":["https://openalex.org/I118136607"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5110769555","display_name":"Xiangxing Lu","orcid":null},"institutions":[{"id":"https://openalex.org/I118136607","display_name":"General Motors (United States)","ror":"https://ror.org/05addee68","country_code":"US","type":"company","lineage":["https://openalex.org/I118136607"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Xiangxing Lu","raw_affiliation_strings":["Vehicle Health Management Group, General Motors Company, Warren, MI, USA"],"affiliations":[{"raw_affiliation_string":"Vehicle Health Management Group, General Motors Company, Warren, MI, USA","institution_ids":["https://openalex.org/I118136607"]}]}],"institution_assertions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.683,"has_fulltext":true,"fulltext_origin":"ngrams","cited_by_count":2,"citation_normalized_percentile":{"value":0.298551,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":70,"max":74},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"8"},"is_retracted":false,"is_paratext":false,"primary_topic":{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9952,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9952,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11372","display_name":"Hydraulic and Pneumatic Systems","score":0.9948,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14470","display_name":"Advanced Data Processing Techniques","score":0.9909,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/solenoid-valve","display_name":"Solenoid valve","score":0.811506},{"id":"https://openalex.org/keywords/fuel-pump","display_name":"Fuel pump","score":0.6909596},{"id":"https://openalex.org/keywords/solenoid","display_name":"Solenoid","score":0.6417259},{"id":"https://openalex.org/keywords/fuel-tank","display_name":"Fuel tank","score":0.45987362},{"id":"https://openalex.org/keywords/control-valves","display_name":"Control valves","score":0.42239553},{"id":"https://openalex.org/keywords/valve-actuator","display_name":"Valve actuator","score":0.4222587}],"concepts":[{"id":"https://openalex.org/C2777112803","wikidata":"https://www.wikidata.org/wiki/Q1430621","display_name":"Solenoid valve","level":2,"score":0.811506},{"id":"https://openalex.org/C2776557616","wikidata":"https://www.wikidata.org/wiki/Q1570062","display_name":"Fuel pump","level":2,"score":0.6909596},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.66045153},{"id":"https://openalex.org/C192144188","wikidata":"https://www.wikidata.org/wiki/Q245739","display_name":"Solenoid","level":2,"score":0.6417259},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.5641831},{"id":"https://openalex.org/C9526370","wikidata":"https://www.wikidata.org/wiki/Q308881","display_name":"Fuel injection","level":2,"score":0.53662854},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.5324142},{"id":"https://openalex.org/C159063594","wikidata":"https://www.wikidata.org/wiki/Q248382","display_name":"Ignition system","level":2,"score":0.4999473},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4747515},{"id":"https://openalex.org/C38673314","wikidata":"https://www.wikidata.org/wiki/Q1411232","display_name":"Fuel tank","level":2,"score":0.45987362},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.4418473},{"id":"https://openalex.org/C126231374","wikidata":"https://www.wikidata.org/wiki/Q1061298","display_name":"Operability","level":2,"score":0.44092554},{"id":"https://openalex.org/C182043768","wikidata":"https://www.wikidata.org/wiki/Q1816388","display_name":"Control valves","level":2,"score":0.42239553},{"id":"https://openalex.org/C173909513","wikidata":"https://www.wikidata.org/wiki/Q645549","display_name":"Valve actuator","level":3,"score":0.4222587},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.37143493},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.25591385},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.23047021},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.17600107},{"id":"https://openalex.org/C146978453","wikidata":"https://www.wikidata.org/wiki/Q3798668","display_name":"Aerospace engineering","level":1,"score":0.090644896},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"is_oa":false,"landing_page_url":"https://doi.org/10.1109/icphm.2018.8448649","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.87}],"grants":[],"datasets":[],"versions":[],"referenced_works_count":15,"referenced_works":["https://openalex.org/W1508063992","https://openalex.org/W1934946773","https://openalex.org/W1965804303","https://openalex.org/W1982150194","https://openalex.org/W1994405077","https://openalex.org/W1995248939","https://openalex.org/W2014547940","https://openalex.org/W2054353914","https://openalex.org/W2067955420","https://openalex.org/W2249627132","https://openalex.org/W2257979135","https://openalex.org/W2743344318","https://openalex.org/W2795854098","https://openalex.org/W3022377941","https://openalex.org/W4292331831"],"related_works":["https://openalex.org/W4390244972","https://openalex.org/W4242528410","https://openalex.org/W3117435126","https://openalex.org/W2387930152","https://openalex.org/W2372919008","https://openalex.org/W2367446538","https://openalex.org/W2360067581","https://openalex.org/W2358766271","https://openalex.org/W2082496135","https://openalex.org/W2017877357"],"abstract_inverted_index":{"Spark":[0],"Ignition":[1],"Direct":[2],"Injection":[3],"(SIDI)":[4],"technology":[5,22],"enables":[6],"better":[7],"fuel":[8,30,40,93,112,123,187],"economy":[9],"and":[10,54,74,88,114,162,181],"tail":[11],"pipe":[12],"emissions":[13],"in":[14,57,108,134],"vehicles":[15],"equipped":[16],"with":[17],"gasoline":[18],"engines.":[19],"The":[20,99],"SIDI":[21],"relies":[23],"on":[24],"the":[25,37,49,52,103,119,125,131,142,151,175],"system's":[26],"ability":[27],"to":[28,48,66,136,154],"deliver":[29],"at":[31,130],"high":[32,38,91,110,185],"pressures.":[33],"Reliable":[34],"performance":[35],"of":[36,51,59,77,90,122,150,177],"pressure":[39,92,111,186],"pump":[41,94,188],"is":[42,97,102,115],"vital":[43],"as":[44],"it":[45],"directly":[46],"relates":[47],"operability":[50],"vehicle,":[53],"customer":[55],"satisfaction":[56],"case":[58],"failure.":[60],"It,":[61],"therefore,":[62],"becomes":[63],"very":[64],"important":[65],"devise":[67],"a":[68,79,109,137,178],"scheme":[69,183],"that":[70,173],"can":[71],"effectively":[72],"diagnose":[73],"prognose":[75],"faults":[76],"such":[78],"component.":[80],"In":[81],"this":[82],"report,":[83],"algorithm":[84],"development":[85,176],"for":[86,117,157,184],"diagnosis":[87],"prognosis":[89,182],"solenoid":[95,100,152,189],"valve":[96,101,153],"presented.":[98],"only":[104],"electronically":[105],"controlled":[106],"actuator":[107],"pump,":[113],"responsible":[116],"trapping":[118],"correct":[120],"amount":[121],"into":[124],"pumping":[126],"chamber":[127],"by":[128,141],"closing":[129],"right":[132],"time":[133],"response":[135],"commanded":[138],"signal":[139],"issued":[140],"engine":[143],"control":[144],"module.":[145],"We":[146],"employ":[147],"current":[148],"feedback":[149],"generate":[155],"schemes":[156],"fault":[158,160,163,179],"detection,":[159],"isolation,":[161],"prediction.":[164],"Results":[165],"are":[166],"presented":[167],"from":[168],"real":[169],"vehicle":[170],"test":[171],"data":[172],"allow":[174],"isolation":[180],"valve.":[190]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2889265207","counts_by_year":[{"year":2021,"cited_by_count":2}],"updated_date":"2024-12-07T15:06:28.980335","created_date":"2018-09-07"}