{"id":"https://openalex.org/W2888962067","doi":"https://doi.org/10.1109/icphm.2018.8448408","title":"Condition Monitoring of Turbine Generator Using Stator Winding Temperature","display_name":"Condition Monitoring of Turbine Generator Using Stator Winding Temperature","publication_year":2018,"publication_date":"2018-06-01","ids":{"openalex":"https://openalex.org/W2888962067","doi":"https://doi.org/10.1109/icphm.2018.8448408","mag":"2888962067"},"language":"en","primary_location":{"is_oa":false,"landing_page_url":"https://doi.org/10.1109/icphm.2018.8448408","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false},"type":"article","type_crossref":"proceedings-article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5101404920","display_name":"Qian Fang","orcid":"https://orcid.org/0000-0001-6995-0037"},"institutions":[],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Fang Qian","raw_affiliation_strings":["Remote Diagnostic Technology Institute, Shanghai Electric Power Generation Group, Shanghai, China"],"affiliations":[{"raw_affiliation_string":"Remote Diagnostic Technology Institute, Shanghai Electric Power Generation Group, Shanghai, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5078946134","display_name":"Yutong Feng","orcid":"https://orcid.org/0000-0002-6839-2106"},"institutions":[{"id":"https://openalex.org/I66867065","display_name":"East China Normal University","ror":"https://ror.org/02n96ep67","country_code":"CN","type":"education","lineage":["https://openalex.org/I66867065"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yutong Feng","raw_affiliation_strings":["East China Normal University, Shanghai, China"],"affiliations":[{"raw_affiliation_string":"East China Normal University, Shanghai, China","institution_ids":["https://openalex.org/I66867065"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5049980307","display_name":"Jun Ling","orcid":"https://orcid.org/0000-0002-0365-1381"},"institutions":[],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Jun Ling","raw_affiliation_strings":["Remote Diagnostic Technology Institute, Shanghai Electric Power Generation Group, Shanghai, China"],"affiliations":[{"raw_affiliation_string":"Remote Diagnostic Technology Institute, Shanghai Electric Power Generation Group, Shanghai, China","institution_ids":[]}]}],"institution_assertions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.342,"has_fulltext":true,"fulltext_origin":"ngrams","cited_by_count":2,"citation_normalized_percentile":{"value":0.50412,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":70,"max":74},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"5"},"is_retracted":false,"is_paratext":false,"primary_topic":{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.9991,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.9991,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9954,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13891","display_name":"Engineering Diagnostics and Reliability","score":0.9932,"subfield":{"id":"https://openalex.org/subfields/2211","display_name":"Mechanics of Materials"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/condition-monitoring","display_name":"Condition Monitoring","score":0.64183617}],"concepts":[{"id":"https://openalex.org/C2776529397","wikidata":"https://www.wikidata.org/wiki/Q190312","display_name":"Stator","level":2,"score":0.8686624},{"id":"https://openalex.org/C2775846686","wikidata":"https://www.wikidata.org/wiki/Q643012","display_name":"Condition monitoring","level":2,"score":0.64183617},{"id":"https://openalex.org/C2780992000","wikidata":"https://www.wikidata.org/wiki/Q17016113","display_name":"Generator (circuit theory)","level":3,"score":0.56013143},{"id":"https://openalex.org/C2778449969","wikidata":"https://www.wikidata.org/wiki/Q130760","display_name":"Turbine","level":2,"score":0.5547463},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.5481003},{"id":"https://openalex.org/C155512373","wikidata":"https://www.wikidata.org/wiki/Q287450","display_name":"Residual","level":2,"score":0.50525314},{"id":"https://openalex.org/C14794904","wikidata":"https://www.wikidata.org/wiki/Q189859","display_name":"Steam turbine","level":2,"score":0.4816105},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.45723495},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.41504866},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.31590807},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.13013175},{"id":"https://openalex.org/C11413529","wikidata":"https://www.wikidata.org/wiki/Q8366","display_name":"Algorithm","level":1,"score":0.12763348},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.11021015},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.10869798},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"is_oa":false,"landing_page_url":"https://doi.org/10.1109/icphm.2018.8448408","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.89}],"grants":[],"datasets":[],"versions":[],"referenced_works_count":11,"referenced_works":["https://openalex.org/W1527152867","https://openalex.org/W1981064558","https://openalex.org/W2011960277","https://openalex.org/W2018108285","https://openalex.org/W2047468395","https://openalex.org/W2072844955","https://openalex.org/W2127064699","https://openalex.org/W2167770337","https://openalex.org/W2281604363","https://openalex.org/W2340400001","https://openalex.org/W4230704549"],"related_works":["https://openalex.org/W772348058","https://openalex.org/W623794290","https://openalex.org/W3186174257","https://openalex.org/W3142988159","https://openalex.org/W2372255233","https://openalex.org/W2361693169","https://openalex.org/W2352258657","https://openalex.org/W2156895031","https://openalex.org/W2040043489","https://openalex.org/W2019514063"],"abstract_inverted_index":{"Condition":[0],"Monitoring":[1],"(CM)":[2],"is":[3,17,40,55,87,94],"critical":[4],"for":[5],"safety":[6],"related":[7],"complex":[8],"components":[9],"in":[10,47],"thermal":[11],"power":[12],"plants.":[13],"Stator":[14],"winding":[15,45,67],"temperature":[16,46,86],"one":[18],"of":[19,24,63],"the":[20,75,85,99],"key":[21],"monitoring":[22,30,101],"indicators":[23],"turbine":[25,64],"generator.":[26],"A":[27,91],"robust":[28],"condition":[29,100],"method":[31,58,102],"that":[32,98],"integrates":[33],"AAKR-based":[34],"empirical":[35],"estimation":[36,79],"and":[37,80,108],"SPRT-based":[38],"detection":[39],"proposed":[41],"to":[42,59,96],"monitor":[43],"stator":[44,66],"this":[48],"paper.":[49],"Auto":[50],"Associative":[51],"Kernel":[52],"Regression":[53],"(AAKR)":[54],"a":[56],"modeling":[57],"construct":[60],"normal":[61],"behavior":[62],"generator":[65],"temperature.":[68],"Sequential":[69],"Probability":[70],"Ratio":[71],"Test":[72],"(SPRT)":[73],"detects":[74],"residual":[76],"between":[77],"AAKR":[78],"measured":[81],"temperature,":[82],"determining":[83],"whether":[84],"behaving":[88],"as":[89],"expected.":[90],"data":[92],"set":[93],"applied":[95],"validate":[97],"can":[103],"detect":[104],"incipient":[105],"failure":[106],"accurately":[107],"simply.":[109]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2888962067","counts_by_year":[{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":1}],"updated_date":"2025-01-06T16:41:56.554083","created_date":"2018-09-07"}