{"id":"https://openalex.org/W2123988271","doi":"https://doi.org/10.1109/ias.2009.5324801","title":"Innovative Differential Protection of Power Transformers Using Low Energy Current Sensors","display_name":"Innovative Differential Protection of Power Transformers Using Low Energy Current Sensors","publication_year":2009,"publication_date":"2009-10-01","ids":{"openalex":"https://openalex.org/W2123988271","doi":"https://doi.org/10.1109/ias.2009.5324801","mag":"2123988271"},"language":"en","primary_location":{"is_oa":false,"landing_page_url":"https://doi.org/10.1109/ias.2009.5324801","pdf_url":null,"source":{"id":"https://openalex.org/S4306418636","display_name":"IEEE Industry Applications Society Annual Meeting","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false},"type":"article","type_crossref":"proceedings-article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5029828180","display_name":"L. Kojovic","orcid":null},"institutions":[{"id":"https://openalex.org/I137596753","display_name":"Eaton (Taiwan)","ror":"https://ror.org/01v23xq73","country_code":"TW","type":"company","lineage":["https://openalex.org/I137596753","https://openalex.org/I4210139942"]}],"countries":["TW"],"is_corresponding":false,"raw_author_name":"Ljubomir Kojovic","raw_affiliation_strings":["Eaton Corporation, Franksville, WI, USA"],"affiliations":[{"raw_affiliation_string":"Eaton Corporation, Franksville, WI, USA","institution_ids":["https://openalex.org/I137596753"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5103583866","display_name":"Martin T. Bishop","orcid":null},"institutions":[],"countries":["US"],"is_corresponding":false,"raw_author_name":"Martin T. Bishop","raw_affiliation_strings":["Cooper Power Syst., Franksville, WI, USA"],"affiliations":[{"raw_affiliation_string":"Cooper Power Syst., Franksville, WI, USA","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5103551041","display_name":"Dharam Sharma","orcid":null},"institutions":[],"countries":["US"],"is_corresponding":false,"raw_author_name":"Dharam Sharma","raw_affiliation_strings":["Nucor-Yamato Steel Co., Armorel, AR, USA"],"affiliations":[{"raw_affiliation_string":"Nucor-Yamato Steel Co., Armorel, AR, USA","institution_ids":[]}]}],"institution_assertions":[],"countries_distinct_count":2,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.181,"has_fulltext":true,"fulltext_origin":"ngrams","cited_by_count":12,"citation_normalized_percentile":{"value":0.894676,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":85,"max":86},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"8"},"is_retracted":false,"is_paratext":false,"primary_topic":{"id":"https://openalex.org/T12692","display_name":"Magnetic Sensor Technology and Applications","score":0.9996,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12692","display_name":"Magnetic Sensor Technology and Applications","score":0.9996,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12510","display_name":"Magneto-Optical Devices for Integrated Photonics","score":0.9894,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12169","display_name":"Non-Destructive Techniques Based on Eddy Current Testing","score":0.986,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/current-sensing","display_name":"Current Sensing","score":0.538294},{"id":"https://openalex.org/keywords/rogowski-coils","display_name":"Rogowski Coils","score":0.535275},{"id":"https://openalex.org/keywords/differential-protection","display_name":"Differential protection","score":0.4841557},{"id":"https://openalex.org/keywords/current-sensor","display_name":"Current sensor","score":0.44106096},{"id":"https://openalex.org/keywords/metering-mode","display_name":"Metering mode","score":0.4224104}],"concepts":[{"id":"https://openalex.org/C56057290","wikidata":"https://www.wikidata.org/wiki/Q2117622","display_name":"Rogowski coil","level":3,"score":0.96468747},{"id":"https://openalex.org/C133770746","wikidata":"https://www.wikidata.org/wiki/Q856535","display_name":"Current transformer","level":4,"score":0.7716256},{"id":"https://openalex.org/C30403606","wikidata":"https://www.wikidata.org/wiki/Q2981904","display_name":"Electromagnetic coil","level":2,"score":0.67080206},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.63146913},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5634415},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.52892196},{"id":"https://openalex.org/C2986957705","wikidata":"https://www.wikidata.org/wiki/Q1756067","display_name":"Differential protection","level":4,"score":0.4841557},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.45781082},{"id":"https://openalex.org/C55000061","wikidata":"https://www.wikidata.org/wiki/Q24894777","display_name":"Current sensor","level":3,"score":0.44106096},{"id":"https://openalex.org/C30905978","wikidata":"https://www.wikidata.org/wiki/Q815598","display_name":"Metering mode","level":2,"score":0.4224104},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.41947794},{"id":"https://openalex.org/C148043351","wikidata":"https://www.wikidata.org/wiki/Q4456944","display_name":"Current (fluid)","level":2,"score":0.32577586},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.3191125},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.20810318},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.14078441},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"is_oa":false,"landing_page_url":"https://doi.org/10.1109/ias.2009.5324801","pdf_url":null,"source":{"id":"https://openalex.org/S4306418636","display_name":"IEEE Industry Applications Society Annual Meeting","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.88,"display_name":"Affordable and clean energy"}],"grants":[],"datasets":[],"versions":[],"referenced_works_count":1,"referenced_works":["https://openalex.org/W2002311605"],"related_works":["https://openalex.org/W4293152413","https://openalex.org/W4252197029","https://openalex.org/W3041890643","https://openalex.org/W2792549605","https://openalex.org/W2608469516","https://openalex.org/W2588890427","https://openalex.org/W2383121925","https://openalex.org/W2363006868","https://openalex.org/W2157945041","https://openalex.org/W2133409896"],"abstract_inverted_index":{"Traditional":[0],"differential":[1,25,53,123],"protection":[2,26,54,71,124],"systems":[3,27,55,72,103,125,133],"are":[4],"applied":[5,37],"on":[6,117,127],"large":[7],"power":[8],"transformers":[9,12,33],"using":[10,64],"current":[11,68,83],"(CTs).":[13],"However,":[14],"because":[15],"of":[16,45,93,113,139],"high":[17,74],"secondary":[18],"currents":[19],"(often":[20],"exceeding":[21],"100":[22],"kA":[23],"RMS)":[24],"for":[28,61,97],"electric":[29],"arc":[30],"furnace":[31],"(EAF)":[32],"have":[34,57,136],"not":[35,135],"been":[36,58],"in":[38,59],"the":[39,43,88,121,131,137],"past":[40],"due":[41],"to":[42],"lack":[44],"commercially":[46],"available":[47],"CTs.":[48],"This":[49],"paper":[50,86,109],"will":[51,148],"present":[52],"that":[56,130],"use":[60,73],"many":[62],"years":[63],"Rogowski":[65,80],"Coil":[66],"(RC)":[67,82],"sensors.":[69,84],"These":[70],"precision":[75],"printed":[76],"circuit":[77],"board":[78],"(PCB)":[79],"coil":[81],"The":[85,108],"reviews":[87],"characteristics,":[89],"designs,":[90],"and":[91,101],"application":[92],"these":[94],"RC":[95,118],"sensors":[96,119],"advanced":[98],"protection,":[99],"control,":[100],"metering":[102],"with":[104,120],"new":[105,114,132],"multifunction":[106],"relays.":[107],"compares":[110],"performance":[111],"characteristics":[112],"solutions":[115],"based":[116,126],"conventional":[122,140],"CTs,":[128],"demonstrating":[129],"do":[134],"limitations":[138],"technology.":[141],"Operating":[142],"experience":[143],"from":[144],"several":[145],"site":[146],"applications":[147],"be":[149],"included.":[150]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2123988271","counts_by_year":[{"year":2024,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2019,"cited_by_count":1},{"year":2018,"cited_by_count":2},{"year":2017,"cited_by_count":1},{"year":2016,"cited_by_count":1},{"year":2015,"cited_by_count":1},{"year":2013,"cited_by_count":1}],"updated_date":"2024-12-03T02:08:21.570692","created_date":"2016-06-24"}