{"id":"https://openalex.org/W2124731769","doi":"https://doi.org/10.1109/10.915711","title":"A new method for pulse oximetry possessing inherent insensitivity to artifact","display_name":"A new method for pulse oximetry possessing inherent insensitivity to artifact","publication_year":2001,"publication_date":"2001-04-01","ids":{"openalex":"https://openalex.org/W2124731769","doi":"https://doi.org/10.1109/10.915711","mag":"2124731769","pmid":"https://pubmed.ncbi.nlm.nih.gov/11322533"},"language":"en","primary_location":{"is_oa":false,"landing_page_url":"https://doi.org/10.1109/10.915711","pdf_url":null,"source":{"id":"https://openalex.org/S5240358","display_name":"IEEE Transactions on Biomedical Engineering","issn_l":"0018-9294","issn":["0018-9294","1558-2531"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false},"type":"article","type_crossref":"journal-article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5000236426","display_name":"Matthew Hayes","orcid":"https://orcid.org/0000-0001-8587-218X"},"institutions":[{"id":"https://openalex.org/I143804889","display_name":"Loughborough University","ror":"https://ror.org/04vg4w365","country_code":"GB","type":"education","lineage":["https://openalex.org/I143804889"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"M.J. Hayes","raw_affiliation_strings":["Dept. of Electron.& Electr. Eng., Loughborough Univ., UK"],"affiliations":[{"raw_affiliation_string":"Dept. of Electron.& Electr. Eng., Loughborough Univ., UK","institution_ids":["https://openalex.org/I143804889"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5112010106","display_name":"P. R. Smith","orcid":null},"institutions":[{"id":"https://openalex.org/I143804889","display_name":"Loughborough University","ror":"https://ror.org/04vg4w365","country_code":"GB","type":"education","lineage":["https://openalex.org/I143804889"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"P.R. Smith","raw_affiliation_strings":["[Optical Engineering Group Department of Electronic and Electrical Engineering, Loughborough University, Leicestershire, UK]"],"affiliations":[{"raw_affiliation_string":"[Optical Engineering Group Department of Electronic and Electrical Engineering, Loughborough University, Leicestershire, UK]","institution_ids":["https://openalex.org/I143804889"]}]}],"institution_assertions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.594,"has_fulltext":true,"fulltext_origin":"ngrams","cited_by_count":121,"citation_normalized_percentile":{"value":0.969487,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":96,"max":97},"biblio":{"volume":"48","issue":"4","first_page":"452","last_page":"461"},"is_retracted":false,"is_paratext":false,"primary_topic":{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11700","display_name":"Hemodynamic Monitoring and Therapy","score":0.9993,"subfield":{"id":"https://openalex.org/subfields/2746","display_name":"Surgery"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T10977","display_name":"Optical Imaging and Spectroscopy Techniques","score":0.9987,"subfield":{"id":"https://openalex.org/subfields/2741","display_name":"Radiology, Nuclear Medicine and Imaging"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/artifact","display_name":"Artifact (error)","score":0.8441616}],"concepts":[{"id":"https://openalex.org/C2779010991","wikidata":"https://www.wikidata.org/wiki/Q2720909","display_name":"Artifact (error)","level":2,"score":0.8441616},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.67357004},{"id":"https://openalex.org/C104267543","wikidata":"https://www.wikidata.org/wiki/Q208163","display_name":"Signal processing","level":3,"score":0.49300477},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.41811025},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.4053108},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.23861933},{"id":"https://openalex.org/C84462506","wikidata":"https://www.wikidata.org/wiki/Q173142","display_name":"Digital signal processing","level":2,"score":0.16784444},{"id":"https://openalex.org/C9390403","wikidata":"https://www.wikidata.org/wiki/Q3966","display_name":"Computer hardware","level":1,"score":0.08663595}],"mesh":[{"descriptor_ui":"D016477","descriptor_name":"Artifacts","qualifier_ui":"","qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D010092","descriptor_name":"Oximetry","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":true},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":"","qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D002138","descriptor_name":"Calibration","qualifier_ui":"","qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D009068","descriptor_name":"Movement","qualifier_ui":"","qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D017711","descriptor_name":"Nonlinear Dynamics","qualifier_ui":"","qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D010092","descriptor_name":"Oximetry","qualifier_ui":"","qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D010991","descriptor_name":"Plethysmography","qualifier_ui":"","qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D010991","descriptor_name":"Plethysmography","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false}],"locations_count":2,"locations":[{"is_oa":false,"landing_page_url":"https://doi.org/10.1109/10.915711","pdf_url":null,"source":{"id":"https://openalex.org/S5240358","display_name":"IEEE Transactions on Biomedical Engineering","issn_l":"0018-9294","issn":["0018-9294","1558-2531"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false},{"is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/11322533","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":["National Institutes of Health"],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/16","score":0.8,"display_name":"Peace, justice, and strong institutions"}],"grants":[],"datasets":[],"versions":[],"referenced_works_count":37,"referenced_works":["https://openalex.org/W1029949466","https://openalex.org/W142570864","https://openalex.org/W1522762113","https://openalex.org/W1527913221","https://openalex.org/W1580053614","https://openalex.org/W1604276129","https://openalex.org/W1678422522","https://openalex.org/W1805226476","https://openalex.org/W1945913920","https://openalex.org/W1950905025","https://openalex.org/W1972514477","https://openalex.org/W1974086535","https://openalex.org/W1983850487","https://openalex.org/W2004663224","https://openalex.org/W2024311649","https://openalex.org/W2030668404","https://openalex.org/W2041259676","https://openalex.org/W2062984588","https://openalex.org/W2064353797","https://openalex.org/W2070395347","https://openalex.org/W2073303519","https://openalex.org/W2075236192","https://openalex.org/W2091099820","https://openalex.org/W2125221003","https://openalex.org/W2127534964","https://openalex.org/W2131516330","https://openalex.org/W2144475623","https://openalex.org/W2148377455","https://openalex.org/W2170354359","https://openalex.org/W2249133779","https://openalex.org/W2333026433","https://openalex.org/W2400398692","https://openalex.org/W2407488597","https://openalex.org/W3152994549","https://openalex.org/W4245091454","https://openalex.org/W4256536061","https://openalex.org/W76831022"],"related_works":["https://openalex.org/W52840052","https://openalex.org/W4308623176","https://openalex.org/W3162837891","https://openalex.org/W3029243869","https://openalex.org/W2748952813","https://openalex.org/W2502336004","https://openalex.org/W2358078963","https://openalex.org/W2019696434","https://openalex.org/W1741504538","https://openalex.org/W1687852313"],"abstract_inverted_index":{"A":[0,86,132],"new":[1,87,130,175],"method":[2],"for":[3,90,95],"pulse":[4,155],"oximetry":[5],"is":[6,38,49,93,102,142,159,171],"presented":[7],"that":[8,48,173],"possesses":[9],"an":[10,44],"inherent":[11],"insensitivity":[12,139],"to":[13,64,104,140,182,192],"corruption":[14,32],"by":[15],"motion":[16,186],"artifact,":[17,187],"a":[18,54,106,149,167,179],"primary":[19],"limitation":[20],"in":[21,40,128,178],"the":[22,34,62,79,109,136,146,164,190],"practical":[23,116],"accuracy":[24,70],"and":[25,68,115,153,161],"clinical":[26,80],"applicability":[27],"of":[28,33,53,73,82,108,118,135,138,148,166,185],"current":[29],"technology.":[30],"Artifact":[31],"underlying":[35],"photoplethysmographic":[36],"signals":[37],"reduced":[39,180],"real":[41],"time,":[42],"using":[43],"electronic":[45,151],"processing":[46,198],"methodology":[47,176],"based":[50],"upon":[51],"inversion":[52],"physical":[55],"artifact":[56,141],"model.":[57],"This":[58],"fundamental":[59],"approach":[60],"has":[61],"potential":[63],"provide":[65],"uninterrupted":[66],"output":[67],"superior":[69],"under":[71],"conditions":[72],"sustained":[74],"subject":[75],"motion,":[76],"therefore,":[77],"widening":[78],"scope":[81],"this":[83,129,174],"useful":[84],"measurement.":[85],"calibration":[88],"technique":[89],"oxygen":[91],"saturation":[92],"developed":[94],"use":[96],"with":[97,145,163,195],"these":[98],"processed":[99],"signals,":[100],"which":[101,158],"shown":[103],"be":[105,193],"generalization":[107],"classical":[110],"interpretation.":[111],"The":[112],"detailed":[113],"theoretical":[114],"issues":[117],"implementation":[119],"are":[120],"then":[121],"explored,":[122],"highlighting":[123],"important":[124],"engineering":[125],"simplifications":[126],"implicit":[127],"approach.":[131],"quantitative":[133],"investigation":[134],"degree":[137],"also":[143],"undertaken,":[144],"aid":[147],"custom":[150],"system":[152],"commercial":[154],"oximeter":[156],"probes,":[157],"compared":[160],"contrasted":[162],"performance":[165],"conventional":[168,196],"implementation.":[169],"It":[170],"demonstrated":[172],"results":[177],"sensitivity":[181],"common":[183],"classes":[184],"while":[188],"retaining":[189],"generality":[191],"combined":[194],"signal":[197],"techniques.":[199]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2124731769","counts_by_year":[{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":2},{"year":2020,"cited_by_count":5},{"year":2019,"cited_by_count":5},{"year":2018,"cited_by_count":7},{"year":2017,"cited_by_count":7},{"year":2016,"cited_by_count":7},{"year":2015,"cited_by_count":9},{"year":2014,"cited_by_count":9},{"year":2013,"cited_by_count":6},{"year":2012,"cited_by_count":10}],"updated_date":"2024-12-09T21:12:58.559402","created_date":"2016-06-24"}