{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,6,30]],"date-time":"2024-06-30T05:16:28Z","timestamp":1719724588322},"reference-count":52,"publisher":"MDPI AG","issue":"11","license":[{"start":{"date-parts":[[2023,5,23]],"date-time":"2023-05-23T00:00:00Z","timestamp":1684800000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"The increasing incidence of cardiovascular diseases (CVDs) is reflected in additional costs for healthcare systems all over the world. To date, pulse transit time (PTT) is considered a key index of cardiovascular health status and for diagnosis of CVDs. In this context, the present study focuses on a novel image analysis-based method for PTT estimation through the application of equivalent time sampling. The method, which post-processes color Doppler videos, was tested on two different setups: a Doppler flow phantom set in pulsatile mode and an in-house arterial simulator. In the former, the Doppler shift was due to the echogenic properties of the blood mimicking fluid only, since the phantom vessels are non-compliant. In the latter, the Doppler signal relied on the wall movement of compliant vessels in which a fluid with low echogenic properties was pumped. Therefore, the two setups allowed the measurement of the flow average velocity (FAV) and the pulse wave velocity (PWV), respectively. Data were collected through an ultrasound diagnostic system equipped with a phased array probe. Experimental outcomes confirm that the proposed method can represent an alternative tool for the local measurement of both FAV in non-compliant vessels and PWV in compliant vessels filled with low echogenic fluids.<\/jats:p>","DOI":"10.3390\/s23115005","type":"journal-article","created":{"date-parts":[[2023,5,23]],"date-time":"2023-05-23T13:13:50Z","timestamp":1684847630000},"page":"5005","source":"Crossref","is-referenced-by-count":1,"title":["A Novel Equivalent Time Sampling-Based Method for Pulse Transit Time Estimation with Applications into the Cardiovascular Disease Diagnosis"],"prefix":"10.3390","volume":"23","author":[{"ORCID":"http:\/\/orcid.org\/0000-0001-7143-5499","authenticated-orcid":false,"given":"Giorgia","family":"Fiori","sequence":"first","affiliation":[{"name":"Department of Industrial, Electronic and Mechanical Engineering, University of Roma Tre, 00146 Rome, Italy"}]},{"ORCID":"http:\/\/orcid.org\/0000-0001-9714-039X","authenticated-orcid":false,"given":"Fabio","family":"Fuiano","sequence":"additional","affiliation":[{"name":"Department of Industrial, Electronic and Mechanical Engineering, University of Roma Tre, 00146 Rome, Italy"}]},{"ORCID":"http:\/\/orcid.org\/0000-0001-7323-5220","authenticated-orcid":false,"given":"Silvia","family":"Conforto","sequence":"additional","affiliation":[{"name":"Department of Industrial, Electronic and Mechanical Engineering, University of Roma Tre, 00146 Rome, Italy"}]},{"ORCID":"http:\/\/orcid.org\/0000-0001-7072-1055","authenticated-orcid":false,"given":"Salvatore Andrea","family":"Sciuto","sequence":"additional","affiliation":[{"name":"Department of Industrial, Electronic and Mechanical Engineering, University of Roma Tre, 00146 Rome, Italy"}]},{"ORCID":"http:\/\/orcid.org\/0000-0002-3542-8854","authenticated-orcid":false,"given":"Andrea","family":"Scorza","sequence":"additional","affiliation":[{"name":"Department of Industrial, Electronic and Mechanical Engineering, University of Roma Tre, 00146 Rome, Italy"}]}],"member":"1968","published-online":{"date-parts":[[2023,5,23]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"688","DOI":"10.1016\/j.jacc.2017.12.015","article-title":"Environmental noise and the cardiovascular system","volume":"71","author":"Schmidt","year":"2018","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1952","DOI":"10.1016\/j.jacc.2017.01.064","article-title":"The aging cardiovascular system: Understanding it at the cellular and clinical levels","volume":"69","author":"Paneni","year":"2017","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"3407306","DOI":"10.1155\/2018\/3407306","article-title":"The impact of obesity on the cardiovascular system","volume":"2018","author":"Csige","year":"2018","journal-title":"J. Diabetes. Res."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"879726","DOI":"10.3389\/fcvm.2022.879726","article-title":"Electronic cigarette use and the risk of cardiovascular diseases","volume":"9","author":"Shao","year":"2022","journal-title":"Front. Cardiovasc. Med."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1161\/CIRCRESAHA.117.305205","article-title":"Exercise and the cardiovascular system: Clinical science and cardiovascular outcomes","volume":"117","author":"Lavie","year":"2015","journal-title":"Circ. Res."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1016\/j.cjco.2021.10.002","article-title":"The cardiovascular system in heat stroke","volume":"4","author":"Marchand","year":"2021","journal-title":"CJC Open"},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Baran, R., Marchal, S., Garcia Campos, S., Rehnberg, E., Tabury, K., Baselet, B., Wehland, M., Grimm, D., and Baatout, S. (2022). The cardiovascular system in space: Focus on in vivo and in vitro studies. Biomedicines, 10.","DOI":"10.3390\/biomedicines10010059"},{"key":"ref_8","unstructured":"World Health Organization (2023, May 10). The Top 10 Causes of Death. Available online: https:\/\/www.who.int\/en\/news-room\/fact-sheets\/detail\/the-top-10-causes-of-death."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1093\/eurheartj\/ehz859","article-title":"European society of cardiology: Cardiovascular disease statistics 2019","volume":"41","author":"Timmis","year":"2020","journal-title":"Eur. Heart J."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"508","DOI":"10.1093\/eurheartj\/ehx628","article-title":"European society of cardiology: Cardiovascular disease statistics 2017","volume":"39","author":"Timmis","year":"2018","journal-title":"Eur. Heart J."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1016\/j.irbm.2014.07.002","article-title":"A review of methods for non-invasive and continuous blood pressure monitoring: Pulse transit time method is promising?","volume":"35","author":"Peter","year":"2014","journal-title":"IRBM"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1109\/RBME.2021.3092208","article-title":"Non-invasive methods for PWV measurement in blood vessel stiffness assessment","volume":"15","author":"Fiori","year":"2022","journal-title":"IEEE Rev. Biomed. Eng."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1007\/s10558-009-9081-4","article-title":"The role of pulse transit time as an index of arterial stiffness during exercise","volume":"9","author":"Kounalakis","year":"2009","journal-title":"Cardiovasc. Eng."},{"key":"ref_14","first-page":"598","article-title":"Is pulse transit time a good indicator of blood pressure changes during short physical exercise in a young population?","volume":"2010","author":"Muehlsteff","year":"2010","journal-title":"Annu. Int. Conf. IEEE Eng. Med. Biol. Soc."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1287","DOI":"10.1161\/HYPERTENSIONAHA.121.17891","article-title":"Carotid-femoral pulse transit time variability predicted mortality and improved risk stratification in the elderly","volume":"78","author":"An","year":"2021","journal-title":"Hypertension"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1152\/japplphysiol.00657.2005","article-title":"Pulse transit time measured from the ECG: An unreliable marker of beat-to-beat blood pressure","volume":"100","author":"Payne","year":"2006","journal-title":"J. Appl. Physiol."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Bang, S., Lee, C., Park, J., Cho, M.C., Yoon, Y.G., and Cho, S.H. (2009, January 26\u201328). A pulse transit time measurement method based on electrocardiography and bioimpedance. Proceedings of the 2009 IEEE Biomedical Circuits and Systems Conference (BioCAS), Beijing, China.","DOI":"10.1109\/BIOCAS.2009.5372060"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"1879","DOI":"10.1109\/TBME.2015.2441951","article-title":"Towards ubiquitous blood pressure monitoring via pulse transit time: Theory and practice","volume":"62","author":"Mukkamala","year":"2015","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1016\/j.medengphy.2017.11.011","article-title":"In vitro validation of measurement of volume elastic modulus using photoplethysmography","volume":"52","author":"Njoum","year":"2018","journal-title":"Med. Eng. Phys."},{"key":"ref_20","first-page":"1","article-title":"A new blood pulsation simulator platform incorporating cardiovascular physiology for evaluating radial pulse waveform","volume":"2019","author":"Yang","year":"2019","journal-title":"J. Healthc. Eng."},{"key":"ref_21","unstructured":"Fuiano, F., Fiori, G., Vurchio, F., Scorza, A., and Sciuto, S.A. (2020, January 14\u201316). Transit time measurement of a pressure wave through an elastic tube based on LVDT sensors. Proceedings of the 24th IMEKO TC4 International Symposium & 22nd International Workshop on ADC and DAC Modelling and Testing, Palermo, Italy. Available online: https:\/\/www.imeko.org\/publications\/tc4-2020\/IMEKO-TC4-2020-60.pdf."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"11144","DOI":"10.1073\/pnas.1814392115","article-title":"Relation between blood pressure and pulse wave velocity for human arteries","volume":"115","author":"Ma","year":"2018","journal-title":"Proc. Natl. Acad. Sci. USA"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"2588","DOI":"10.1093\/eurheartj\/ehl254","article-title":"European Network for Non-invasive Investigation of Large Arteries. Expert consensus document on arterial stiffness: Methodological issues and clinical applications","volume":"27","author":"Laurent","year":"2006","journal-title":"Eur. Heart J."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"698","DOI":"10.1161\/HYP.0000000000000033","article-title":"Recommendations for improving and standardizing vascular research on arterial stiffness: A scientific statement from the American Heart Association","volume":"66","author":"Townsend","year":"2015","journal-title":"Hypertension"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1097\/01.hjh.0000199805.03058.78","article-title":"Is arterial stiffness ready for daily clinical practice?","volume":"24","year":"2006","journal-title":"J. Hypertens."},{"key":"ref_26","doi-asserted-by":"crossref","unstructured":"Fung, Y.C. (1997). Biomechanics: Circulation, Springer. [2nd ed.].","DOI":"10.1007\/978-1-4757-2696-1"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"1109","DOI":"10.1016\/j.echo.2016.07.013","article-title":"Echocardiographic assessment of aortic pulse-wave velocity: Validation against invasive pressure measurements","volume":"29","author":"Styczynski","year":"2016","journal-title":"J. Am. Soc. Echocardiogr."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"325","DOI":"10.1016\/j.echo.2013.02.003","article-title":"American Society of Echocardiography Cardiovascular Technology and Research Summit: A roadmap for 2020","volume":"26","author":"Pellikka","year":"2013","journal-title":"J. Am. Soc. Echocardiogr."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"1547","DOI":"10.1097\/HJH.0000000000002081","article-title":"Current assessment of pulse wave velocity: Comprehensive review of validation studies","volume":"37","author":"Milan","year":"2019","journal-title":"J. Hypertens."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"114009","DOI":"10.1088\/1361-6579\/aae8a0","article-title":"A method for determining local pulse wave velocity in human ascending aorta from sequential ultrasound measurements of diameter and velocity","volume":"39","author":"Negoita","year":"2018","journal-title":"Physiol. Meas."},{"key":"ref_31","doi-asserted-by":"crossref","unstructured":"Fuiano, F., Fiori, G., Scorza, A., and Sciuto, S.A. (2021, January 7\u20139). A novel experimental set-up for Young modulus assessment through transit time measurements in biomedical applications. Proceedings of the 2021 IEEE International Workshop on Metrology for Industry 4.0 and IoT (MetroInd4.0&IoT), Rome, Italy.","DOI":"10.1109\/MetroInd4.0IoT51437.2021.9488460"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"124","DOI":"10.1177\/016173469401600205","article-title":"Ultrasonic measurement of forced diameter variations in an elastic tube","volume":"16","author":"Berrios","year":"1994","journal-title":"Ultrason. Imaging"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"012018","DOI":"10.1088\/1742-6596\/421\/1\/012018","article-title":"Measurement system for an in-vitro characterization of the biomechanics and hemodynamics of arterial bifurcations","volume":"421","author":"Balay","year":"2013","journal-title":"J. Phys. Conf. Ser."},{"key":"ref_34","doi-asserted-by":"crossref","unstructured":"Kikkawa, T., Toya, A., and Xiao, X. (2014, January 28\u201331). CMOS equivalent time sampling circuit for breast cancer detection. Proceedings of the 2014 IEEE International Conference on Solid-State and Integrated Circuit Technology (ICSICT), Guilin, China.","DOI":"10.1109\/ICSICT.2014.7021347"},{"key":"ref_35","doi-asserted-by":"crossref","unstructured":"Masui, Y., Toya, A., Sugawara, M., Maeda, T., Ono, M., Murasaka, Y., Iwata, A., and Kikkawa, T. (2017, January 19\u201321). Differential equivalent time sampling receiver for breast cancer detection. Proceedings of the 2017 IEEE Biomedical Circuits and Systems Conference (BioCAS), Turin, Italy.","DOI":"10.1109\/BIOCAS.2017.8325058"},{"key":"ref_36","doi-asserted-by":"crossref","unstructured":"Fiori, G., Fuiano, F., Scorza, A., Schmid, M., Conforto, S., and Sciuto, S.A. (2020, January 1\u20133). ECG waveforms reconstruction based on equivalent time sampling. Proceedings of the 2020 IEEE International Symposium on Medical Measurements and Applications (MeMeA), Bari, Italy.","DOI":"10.1109\/MeMeA49120.2020.9137260"},{"key":"ref_37","unstructured":"Sun Nuclear Corporation (2023, May 10). Doppler 403 \u2122 & Mini-Doppler 1430 \u2122 Flow Phantoms. Available online: https:\/\/www.sunnuclear.com\/uploads\/documents\/datasheets\/Diagnostic\/DopplerFlow_Phantoms_113020.pdf."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"100240","DOI":"10.1016\/j.measen.2021.100240","article-title":"A preliminary approach based on numerical simulations for the design of a PWV-varying arterial simulator","volume":"18","author":"Fuiano","year":"2021","journal-title":"Meas. Sens."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1097\/RUQ.0b013e3182a80d34","article-title":"Ultrasound artifacts: Classification, applied physics with illustrations, and imaging appearances","volume":"30","author":"Prabhu","year":"2014","journal-title":"Ultrasound Q."},{"key":"ref_40","unstructured":"Evans, D.H., and McDicken, W.N. (2000). Doppler Ultrasound: Physics, Instrumentation and Signal Processing, John Wiley & Sons Ltd.. [2nd ed.]."},{"key":"ref_41","doi-asserted-by":"crossref","unstructured":"Fiori, G., Pica, A., Sciuto, S.A., Marinozzi, F., Bini, F., and Scorza, A. (2022). A comparative study on a novel quality assessment protocol based on image analysis methods for color Doppler ultrasound diagnostic systems. Sensors, 22.","DOI":"10.3390\/s22249868"},{"key":"ref_42","doi-asserted-by":"crossref","unstructured":"Fiori, G., Scorza, A., Schmid, M., Galo, J., Conforto, S., and Sciuto, S.A. (2022., January 12\u201314). A preliminary study on the blind angle estimation for quality assessment of color Doppler ultrasound diagnostic systems. Proceedings of the 25th IMEKO TC4 International Symposium & 23rd International Workshop on ADC and DAC Modelling and Testing, Brescia, Italy. Available online: https:\/\/www.imeko.org\/publications\/tc4-2022\/IMEKO-TC4-2022-60.pdf.","DOI":"10.21014\/tc4-2022.60"},{"key":"ref_43","doi-asserted-by":"crossref","unstructured":"Fiori, G., Scorza, A., Schmid, M., Galo, J., Conforto, S., and Sciuto, S.A. (2022., January 12\u201314). A first approach to the registration error assessment in quality controls of color Doppler ultrasound diagnostic systems. Proceedings of the 25th IMEKO TC4 International Symposium & 23rd International Workshop on ADC and DAC Modelling and Testing, Brescia, Italy. Available online: https:\/\/www.imeko.org\/publications\/tc4-2022\/IMEKO-TC4-2022-29.pdf.","DOI":"10.21014\/tc4-2022.29"},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"4003108","DOI":"10.1109\/TIM.2023.3250309","article-title":"A comparative study on depth of penetration measurements in diagnostic ultrasounds through the adaptive SNR threshold method","volume":"72","author":"Fiori","year":"2023","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_45","unstructured":"Taylor, J.R. (1996). An Introduction to Error Analysis: The Study of Uncertainties in Physical Measurements, University Science Books. [2nd ed.]."},{"key":"ref_46","doi-asserted-by":"crossref","unstructured":"Fuiano, F., Scorza, A., and Sciuto, S.A. (2022, January 7\u20139). Design of a novel PWV-varying arterial simulator for biomedical applications: A preliminary study. Proceedings of the 2022 IEEE International Workshop on Metrology for Industry 4.0 & IoT (MetroInd4.0&IoT), Trento, Italy.","DOI":"10.1109\/MetroInd4.0IoT54413.2022.9831680"},{"key":"ref_47","doi-asserted-by":"crossref","unstructured":"Battista, L., Sciuto, S.A., and Scorza, A. (2011, January 30\u201331). Preliminary evaluation of a fiber-optic sensor for flow measurements in pulmonary ventilators. Proceedings of the 2011 IEEE International Symposium on Medical Measurements and Applications (MeMeA), Bari, Italy.","DOI":"10.1109\/MeMeA.2011.5966671"},{"key":"ref_48","doi-asserted-by":"crossref","unstructured":"The Reference Values for Arterial Stiffness\u2019 Collaboration (2010). Determinants of pulse wave velocity in healthy people and in the presence of cardiovascular risk factors: \u2018establishing normal and reference values\u2019. Eur. Heart J., 31, 2338\u20132350.","DOI":"10.1093\/eurheartj\/ehq165"},{"key":"ref_49","first-page":"653239","article-title":"Reference values of pulse wave velocity in healthy people from an urban and rural argentinean population","volume":"2014","author":"Galli","year":"2014","journal-title":"Int. J. Hypertens."},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"1050","DOI":"10.1007\/s00392-018-1278-3","article-title":"Parameters of pulse wave velocity: Determinants and reference values assessed in the population-based study LIFE-Adult","volume":"107","author":"Baier","year":"2018","journal-title":"Clin. Res. Cardiol."},{"key":"ref_51","first-page":"41","article-title":"Pulse wave velocity in atherosclerosis","volume":"6","author":"Kim","year":"2019","journal-title":"Cardiovasc. Med."},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"555","DOI":"10.1007\/s40846-015-0086-8","article-title":"Novel methods for pulse wave velocity measurement","volume":"35","author":"Pereira","year":"2015","journal-title":"J. Med. Biol. Eng."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/11\/5005\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,23]],"date-time":"2023-05-23T13:19:10Z","timestamp":1684847950000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/11\/5005"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,5,23]]},"references-count":52,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2023,6]]}},"alternative-id":["s23115005"],"URL":"https:\/\/doi.org\/10.3390\/s23115005","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,5,23]]}}}