{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,9,16]],"date-time":"2023-09-16T01:34:03Z","timestamp":1694828043139},"reference-count":24,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2018,10,15]],"date-time":"2018-10-15T00:00:00Z","timestamp":1539561600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/501100004608","name":"Natural Science Foundation of Jiangsu Province","doi-asserted-by":"publisher","award":["BK20151181"],"id":[{"id":"10.13039\/501100004608","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Med Biol Eng Comput"],"published-print":{"date-parts":[[2019,3]]},"DOI":"10.1007\/s11517-018-1912-2","type":"journal-article","created":{"date-parts":[[2018,10,15]],"date-time":"2018-10-15T05:00:36Z","timestamp":1539579636000},"page":"643-651","update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Imaging study of pseudo-CT images of superposed ultrasound deformation fields acquired in radiotherapy based on step-by-step local registration"],"prefix":"10.1007","volume":"57","author":[{"given":"Hongfei","family":"Sun","sequence":"first","affiliation":[]},{"given":"Tao","family":"Lin","sequence":"additional","affiliation":[]},{"given":"Kai","family":"Xie","sequence":"additional","affiliation":[]},{"given":"Liugang","family":"Gao","sequence":"additional","affiliation":[]},{"given":"Jianfeng","family":"Sui","sequence":"additional","affiliation":[]},{"given":"Xinye","family":"Ni","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2018,10,15]]},"reference":[{"issue":"2","key":"1912_CR1","doi-asserted-by":"publisher","first-page":"151","DOI":"10.1007\/s12194-009-0059-0","volume":"2","author":"A Takemura","year":"2009","unstructured":"Takemura A, Shoji S, Ueda S, Kurata Y, Kumano T, Takamatsu S, Suzuki M (2009) Effect of daily setup errors on individual dose distribution in conventional radiotherapy: an initial study[J]. Radiol Phys Technol. 2(2):151\u2013158","journal-title":"Radiol Phys Technol."},{"issue":"3","key":"1912_CR2","doi-asserted-by":"publisher","first-page":"715","DOI":"10.1016\/S0360-3016(97)00567-1","volume":"41","author":"D Yan","year":"1998","unstructured":"Yan D, Ziaja E, Jaffray D, Wong J, Brabbins D, Vicini F, Martinez A (1998) The use of adaptive radiation therapy to reduce setup error: a prospective clinical study[J]. Int J Radiat Oncol Biol Phys 41(3):715\u2013720","journal-title":"Int J Radiat Oncol Biol Phys"},{"issue":"6","key":"1912_CR3","doi-asserted-by":"publisher","DOI":"10.1118\/1.4804215","volume":"40","author":"H Yan","year":"2013","unstructured":"Yan H, Zhen X, Cervi\u00f1o L, Jiang SB, Jia X (2013) Progressive cone beam CT dose control in image-guided radiation therapy[J]. Med Phys 40(6):060701","journal-title":"Med Phys"},{"key":"1912_CR4","doi-asserted-by":"publisher","first-page":"S854","DOI":"10.1016\/S0167-8140(16)33073-0","volume":"119","author":"S Meroni","year":"2016","unstructured":"Meroni S, Mongioj V, Giandini T, Bonfantini F, Cavallo A, Carrara M, Stucchi C, Cavatorta C, Pignoli E (2016) EP-1822: limits and potentialities of the use of CBCT for dose calculation in adaptive radiotherapy[J]. Radiother Oncol 119:S854\u2013S855","journal-title":"Radiother Oncol"},{"key":"1912_CR5","doi-asserted-by":"crossref","unstructured":"Pennec X, Cachier P, Ayache N (2001) Tracking brain deformations in time-sequences of 3D US images[J]. 24(4\u20135):801\u2013813","DOI":"10.1007\/3-540-45729-1_16"},{"key":"1912_CR6","unstructured":"Andreasen D, Edmund JM, Zografos V et al (2016) Computed tomography synthesis from magnetic resonance images in the pelvis using multiple random forests and auto-context features[C]\/\/SPIE medical imaging. International Society for Optics and Photonics 9784:978417"},{"key":"1912_CR7","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1016\/j.media.2017.05.004","volume":"41","author":"X Cao","year":"2017","unstructured":"Cao X, Yang J, Gao Y, Guo Y, Wu G, Shen D (2017) Dual-core steered non-rigid registration for multi-modal images via bi-directional image synthesis[J]. Med Image Anal 41:18\u201331","journal-title":"Med Image Anal"},{"issue":"1","key":"1912_CR8","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1186\/s13014-015-0380-1","volume":"10","author":"M Li","year":"2015","unstructured":"Li M, Ballhausen H, Hegemann NS, Ganswindt U, Manapov F, Tritschler S, Roosen A, Gratzke C, Reiner M, Belka C (2015) A comparative assessment of prostate positioning guided by three-dimensional ultrasound and cone beam CT[J]. Radiat Oncol 10(1):82\u201383","journal-title":"Radiat Oncol"},{"issue":"4","key":"1912_CR9","doi-asserted-by":"publisher","first-page":"1913","DOI":"10.1118\/1.4944064","volume":"43","author":"MS d Van","year":"2016","unstructured":"Van d MS, Camps SM, van Elmpt WJ et al (2016) Simulation of pseudo-CT images based on deformable image registration of ultrasound images: a proof of concept for transabdominal ultrasound imaging of the prostate during radiotherapy.[J]. Med Phys 43(4):1913\u20131920","journal-title":"Med Phys"},{"key":"1912_CR10","doi-asserted-by":"crossref","unstructured":"Camps S, Meer SVD, Verhaegen F, et al. (2016) Various approaches for pseudo-CT scan creation based on ultrasound to ultrasound deformable image registration between different treatment time points for radiotherapy treatment plan adaptation in prostate cancer patients[J]. 2(3):035018","DOI":"10.1088\/2057-1976\/2\/3\/035018"},{"issue":"1","key":"1912_CR11","doi-asserted-by":"publisher","first-page":"8","DOI":"10.4103\/0256-4602.48464","volume":"26","author":"V Shrimali","year":"2009","unstructured":"Shrimali V, Anand RS, Kumar V (2009) Current trends in segmentation of medical ultrasound B-mode images: a review[J]. IETE Tech Rev 26(1):8\u201317","journal-title":"IETE Tech Rev"},{"issue":"1","key":"1912_CR12","doi-asserted-by":"publisher","first-page":"196","DOI":"10.1109\/TMI.2009.2035616","volume":"29","author":"S Klein","year":"2010","unstructured":"Klein S, Staring M, Murphy K, Viergever MA, Pluim J (2010) Elastix: a toolbox for intensity-based medical image registration[J]. IEEE Trans Med Imaging 29(1):196\u2013204","journal-title":"IEEE Trans Med Imaging"},{"issue":"50","key":"1912_CR13","first-page":"50","volume":"7","author":"DP Shamonin","year":"2013","unstructured":"Shamonin DP, Bron EE, Lelieveldt BPF et al (2013) Fast parallel image registration on CPU and GPU for diagnostic classification of Alzheimer's disease[J]. Front Neuroendocrinol 7(50):50\u201360","journal-title":"Front Neuroendocrinol"},{"issue":"4","key":"1912_CR14","doi-asserted-by":"publisher","first-page":"100","DOI":"10.1120\/jacmp.v13i4.3753","volume":"13","author":"D Robinson","year":"2012","unstructured":"Robinson D, Liu D, Steciw S, Field C, Daly H, Saibishkumar EP, Fallone G, Parliament M, Amanie J (2012) An evaluation of the clarity 3D ultrasound system for prostate localization[J]. J Appl Clin Med Phys 13(4):100\u2013112","journal-title":"J Appl Clin Med Phys"},{"issue":"10","key":"1912_CR15","doi-asserted-by":"publisher","DOI":"10.1118\/1.4895824","volume":"41","author":"Z Zhang","year":"2014","unstructured":"Zhang Z, Liu F, Tsui H, Lau Y, Song X (2014) A multiscale adaptive mask method for rigid intraoperative ultrasound and preoperative CT image registration[J]. Med Phys 41(10):102903","journal-title":"Med Phys"},{"key":"1912_CR16","unstructured":"Kadir T, Zisserman A, Brady M (2004) An affine invariant salient region detector[C]\/\/ Proc European Conference on Computer Vision. 228\u2013241"},{"key":"1912_CR17","unstructured":"Lu B, Wang H, Lin Z (2011) High order Gaussian curvature flow for image smoothing[C]\/\/ international conference on multimedia technology. IEEE:5888\u20135891"},{"key":"1912_CR18","doi-asserted-by":"crossref","unstructured":"Vik T, Kabus S, Berg J V, et al. Validation and comparison of registration methods for free-breathing 4D lung CT[J]. Proc Spie, 2008, 6914(6914):69142P-1-69142P-10","DOI":"10.1117\/12.767787"},{"issue":"6","key":"1912_CR19","doi-asserted-by":"publisher","first-page":"3331","DOI":"10.1118\/1.4955602","volume":"43","author":"S Riyahi","year":"2016","unstructured":"Riyahi S, Choi W, Bhooshan N, Tan S, Zhang H, Lu W (2016) Comparison of registration methods for modeling pathologic response of esophageal cancer to chemoradiation therapy[J]. Med Phys 43(6):3331\u20133339","journal-title":"Med Phys"},{"issue":"1","key":"1912_CR20","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1186\/1748-717X-9-48","volume":"9","author":"C Dong","year":"2014","unstructured":"Dong C, Wang R, Meng X et al (2014) A comparison of liver protection among 3-D conformal radiotherapy, intensity-modulated radiotherapy and RapidArc for hepatocellular carcinoma[J]. Radiat Oncol 9(1):48","journal-title":"Radiat Oncol"},{"issue":"1","key":"1912_CR21","doi-asserted-by":"publisher","first-page":"330","DOI":"10.1118\/1.3671929","volume":"39","author":"SP Robertson","year":"2012","unstructured":"Robertson SP, Weiss E, Hugo GD (2012) Localization accuracy from automatic and semi-automatic rigid registration of locally-advanced lung cancer targets during image-guided radiation therapy[J]. Med Phys 39(1):330\u2013341","journal-title":"Med Phys"},{"issue":"3","key":"1912_CR22","first-page":"249","volume":"12","author":"G Geraily","year":"2014","unstructured":"Geraily G, Mirzapour M, Mahdavi SR et al (2014) Monte Carlo study on beam hardening effect of physical wedges[J]. Iran J Radiat Res 12(3):249\u2013256","journal-title":"Iran J Radiat Res"},{"issue":"3","key":"1912_CR23","doi-asserted-by":"publisher","first-page":"900","DOI":"10.1118\/1.2839146","volume":"35","author":"J Aubry","year":"2008","unstructured":"Aubry J, Pouliot J, Beaulieu L (2008) Correction of megavoltage cone-beam CT images for dose calculation in the head and neck region[J]. Med Phys 35(3):900\u2013907","journal-title":"Med Phys"},{"issue":"6","key":"1912_CR24","doi-asserted-by":"publisher","first-page":"3242","DOI":"10.1118\/1.4924002","volume":"42","author":"J Zhang","year":"2015","unstructured":"Zhang J, Zhang W, Lu J (2015) A correction algorithm for Kilovoltage cone-beam computed tomography dose calculations in cervical Cancer patients[J]. Med Phys 42(6):3242\u20133242","journal-title":"Med Phys"}],"container-title":["Medical & Biological Engineering & Computing"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11517-018-1912-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-018-1912-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-018-1912-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,10,14]],"date-time":"2019-10-14T23:21:25Z","timestamp":1571095285000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11517-018-1912-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,10,15]]},"references-count":24,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2019,3]]}},"alternative-id":["1912"],"URL":"https:\/\/doi.org\/10.1007\/s11517-018-1912-2","relation":{},"ISSN":["0140-0118","1741-0444"],"issn-type":[{"value":"0140-0118","type":"print"},{"value":"1741-0444","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,10,15]]},"assertion":[{"value":"9 February 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 October 2018","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 October 2018","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The protocol of this study was approved by the medical ethics committee of Second People\u2019s Hospital of Changzhou, Nanjing Medical University (2017-002-01).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"The authors declare that they have no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"Not applicable.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}}]}}