{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,9,10]],"date-time":"2024-09-10T14:57:31Z","timestamp":1725980251291},"publisher-location":"Cham","reference-count":25,"publisher":"Springer International Publishing","isbn-type":[{"type":"print","value":"9783319933986"},{"type":"electronic","value":"9783319933993"}],"license":[{"start":{"date-parts":[[2018,1,1]],"date-time":"2018-01-01T00:00:00Z","timestamp":1514764800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2018,1,1]],"date-time":"2018-01-01T00:00:00Z","timestamp":1514764800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2018]]},"DOI":"10.1007\/978-3-319-93399-3_40","type":"book-chapter","created":{"date-parts":[[2018,6,5]],"date-time":"2018-06-05T10:39:59Z","timestamp":1528195199000},"page":"464-475","update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Suitability of a Tool-Speed-Dependent Force Model for VR-Based Soft-Tissue Dissection"],"prefix":"10.1007","author":[{"given":"Fernando","family":"Trejo","sequence":"first","affiliation":[]},{"given":"Yaoping","family":"Hu","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2018,6,6]]},"reference":[{"key":"40_CR1","first-page":"158","volume":"6","author":"K Miller","year":"2000","unstructured":"Miller, K.: Biomechanics of soft tissue. Med. Sci. Monit. 6, 158\u2013167 (2000)","journal-title":"Med. Sci. Monit."},{"key":"40_CR2","first-page":"1707","volume":"51","author":"AM Okamura","year":"2004","unstructured":"Okamura, A.M., Simone, C., O\u2019Leary, M.D.: Force modeling for needle insertion into soft tissue. IEEE TBME 51, 1707\u20131716 (2004)","journal-title":"IEEE TBME"},{"key":"40_CR3","doi-asserted-by":"publisher","first-page":"62","DOI":"10.1016\/j.media.2006.09.005","volume":"11","author":"JT Hing","year":"2007","unstructured":"Hing, J.T., Brooks, A.D., Desai, J.P.: A biplanar fluoroscopic approach for the measurement, modeling, and simulation of needle and soft-tissue interaction. Med. Image Anal. 11, 62\u201378 (2007)","journal-title":"Med. Image Anal."},{"issue":"2","key":"40_CR4","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1002\/rcs.1568","volume":"10","author":"Hani J. Marcus","year":"2014","unstructured":"Marcus, H.J. (et al.): Forces exerted during microneurosurgery: a cadaver study. Int. J. Med. Robotics Comput. Assist. Surg. 10, 251\u2013256 (2014)","journal-title":"The International Journal of Medical Robotics and Computer Assisted Surgery"},{"key":"40_CR5","doi-asserted-by":"publisher","first-page":"463","DOI":"10.1162\/pres.17.5.463","volume":"17","author":"S Misra","year":"2008","unstructured":"Misra, S., Ramesh, K.T., Okamura, A.M.: Modeling of tool-tissue interactions for computer-based surgical simulation: a literature review. Presence Teleop. Virt. 17, 463\u2013491 (2008)","journal-title":"Presence Teleop. Virt."},{"key":"40_CR6","doi-asserted-by":"publisher","first-page":"102","DOI":"10.1097\/MOU.0b013e32831a478c","volume":"19","author":"AM Okamura","year":"2009","unstructured":"Okamura, A.M.: Haptic feedback in robot-assisted minimally invasive surgery. Cure. Opin. Urol. 19, 102\u2013107 (2009)","journal-title":"Cure. Opin. Urol."},{"key":"40_CR7","first-page":"56","volume":"24","author":"C Basdogan","year":"2004","unstructured":"Basdogan, C., De, S., Kim, J., Muniyandi, M., Kim, H., Srinivasan, M.A.: Haptics in minimally invasive surgical simulation and training. IEEE CG&A 24, 56\u201364 (2004)","journal-title":"IEEE CG&A"},{"key":"40_CR8","first-page":"32","volume":"71","author":"S Delorme","year":"2012","unstructured":"Delorme, S., Laroche, D., DiRaddo, R., Del Maestro, R.F.: NeuroTouch: a physics-based virtual simulator for cranial microneurosurgery training. Neurosurg. 71, 32\u201342 (2012)","journal-title":"Neurosurg."},{"key":"40_CR9","doi-asserted-by":"publisher","first-page":"297","DOI":"10.1007\/s11548-010-0508-6","volume":"6","author":"E Basafa","year":"2011","unstructured":"Basafa, E., Farahmand, F.: Real-time simulation of the nonlinear visco-elastic deformations of soft tissues. Int. J. CARS 6, 297\u2013307 (2011)","journal-title":"Int. J. CARS"},{"key":"40_CR10","first-page":"85","volume":"14","author":"NM Vafai","year":"2010","unstructured":"Vafai, N.M., Payandeh, S.: Toward the development of interactive virtual dissection with haptic feedback. VR 14, 85\u2013103 (2010)","journal-title":"VR"},{"key":"40_CR11","doi-asserted-by":"publisher","first-page":"260","DOI":"10.1016\/j.cmpb.2013.01.018","volume":"112","author":"Z Wang","year":"2013","unstructured":"Wang, Z., Sun, Z., Phee, S.J.: Haptic feedback and control of a flexible surgical endoscopic robot. Comput. Methods Programs Biomed. 112, 260\u2013271 (2013)","journal-title":"Comput. Methods Programs Biomed."},{"key":"40_CR12","doi-asserted-by":"publisher","first-page":"217","DOI":"10.1155\/2010\/705389","volume":"7","author":"L Santos-Carreras","year":"2010","unstructured":"Santos-Carreras, L., Beira, R., Sengul, A., Gassert, R., Bleuler, H.: Influence of force and torque feedback on operator performance in a VR-based suturing task. Appl. Bionics Biomech. 7, 217\u2013230 (2010)","journal-title":"Appl. Bionics Biomech."},{"key":"40_CR13","first-page":"934","volume":"57","author":"M Mahvash","year":"2010","unstructured":"Mahvash, M., Dupont, P.E.: Mechanics of dynamic needle insertion into biological material. IEEE TBME 57, 934\u2013943 (2010)","journal-title":"IEEE TBME"},{"key":"40_CR14","first-page":"1","volume":"2","author":"M Mahvash","year":"2001","unstructured":"Mahvash, M., Hayward, V.: Haptic rendering of cutting: a fracture mechanics approach. Haptics-e 2, 1\u201312 (2001)","journal-title":"Haptics-e"},{"key":"40_CR15","doi-asserted-by":"crossref","unstructured":"Trejo, F., Hu, Y.: Towards an analytic haptic model for force rendering of soft-tissue dissection. In: Proceedings of the IEEE International Conference SMC, pp. 1098\u20131103 (2016)","DOI":"10.1109\/SMC.2016.7844389"},{"key":"40_CR16","doi-asserted-by":"publisher","first-page":"882","DOI":"10.1016\/j.medengphy.2011.09.030","volume":"34","author":"C Gokgol","year":"2012","unstructured":"Gokgol, C., Basdogan, C., Canadinc, D.: Estimation of fracture toughness of liver tissue: experiments and validation. Med. Eng. Phys. 34, 882\u2013891 (2012)","journal-title":"Med. Eng. Phys."},{"key":"40_CR17","first-page":"349","volume":"54","author":"T Chanthasopeephan","year":"2007","unstructured":"Chanthasopeephan, T., Desai, J.P., Lau, A.C.W.: Modeling soft-tissue deformation prior to cutting for surgical simulation: finite element analysis and study of cutting parameters. IEEE TBME 54, 349\u2013359 (2007)","journal-title":"IEEE TBME"},{"key":"40_CR18","doi-asserted-by":"publisher","first-page":"1369","DOI":"10.1016\/S0021-9290(00)00120-2","volume":"33","author":"K Miller","year":"2000","unstructured":"Miller, K., Chinzei, K., Orssengo, G., Bednarz, P.: Mechanical properties of brain tissue in-vivo: experiment and computer simulation. J. Biomech. 33, 1369\u20131376 (2000)","journal-title":"J. Biomech."},{"key":"40_CR19","doi-asserted-by":"publisher","first-page":"252","DOI":"10.1162\/pres.16.3.252","volume":"16","author":"CR Wagner","year":"2007","unstructured":"Wagner, C.R., Stylopoulos, N., Jackson, P.G., Howe, R.D.: The benefit of force feedback in surgery: examination of blunt Dissection. Presence 16, 252\u2013262 (2007)","journal-title":"Presence"},{"key":"40_CR20","doi-asserted-by":"publisher","first-page":"S1","DOI":"10.4103\/2152-7806.151321","volume":"6","author":"GR Sutherland","year":"2015","unstructured":"Sutherland, G.R., Maddahi, Y., Gan, L.S., Lama, S., Zareinia, K.: Robotics in the neurosurgical treatment of glioma. Surg. Neurol. Int. 6, S1\u2013S8 (2015)","journal-title":"Surg. Neurol. Int."},{"key":"40_CR21","volume-title":"Statistical Rules of Thumb","author":"G Belle Van","year":"2011","unstructured":"Van Belle, G.: Statistical Rules of Thumb. Wiley, New Jersey (2011)"},{"key":"40_CR22","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1207\/s15327108ijap0303_3","volume":"3","author":"RS Kennedy","year":"1993","unstructured":"Kennedy, R.S., Lane, N.E., Berbaum, K.S., Lilienthal, M.G.: Simulator sickness questionnaire: an enhanced method for quantifying simulator sickness. Int. J. Aviat. Psychol. 3, 203\u2013220 (1993)","journal-title":"Int. J. Aviat. Psychol."},{"issue":"9","key":"40_CR23","doi-asserted-by":"publisher","first-page":"904","DOI":"10.1177\/154193120605000909","volume":"50","author":"Sandra G. Hart","year":"2006","unstructured":"Hart, S.G.: NASA-Task load index (NASA-TLX); 20 years later. In: Proceedings of the Human Factors and Ergonomics Society Annual Meeting, pp. 904\u2013908 (2006)","journal-title":"Proceedings of the Human Factors and Ergonomics Society Annual Meeting"},{"key":"40_CR24","doi-asserted-by":"publisher","first-page":"205","DOI":"10.1080\/02643294.2017.1376630","volume":"34","author":"M Prunty","year":"2017","unstructured":"Prunty, M., Barnett, A.L.: Understanding handwriting difficulties: a comparison of children with and without motor impairment. Cogn. Neuropsychol. 34, 205\u2013218 (2017)","journal-title":"Cogn. Neuropsychol."},{"key":"40_CR25","doi-asserted-by":"publisher","first-page":"555","DOI":"10.1162\/105474602321050695","volume":"11","author":"MC Cavusoglu","year":"2002","unstructured":"Cavusoglu, M.C., Feygin, D., Tendick, F.: A critical study of the mechanical and electrical properties of the phantom haptic interface and improvements for high-performance control. Presence 11, 555\u2013568 (2002)","journal-title":"Presence"}],"container-title":["Lecture Notes in Computer Science","Haptics: Science, Technology, and Applications"],"original-title":[],"link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-319-93399-3_40","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2018,6,30]],"date-time":"2018-06-30T07:30:41Z","timestamp":1530343841000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/978-3-319-93399-3_40"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018]]},"ISBN":["9783319933986","9783319933993"],"references-count":25,"URL":"https:\/\/doi.org\/10.1007\/978-3-319-93399-3_40","relation":{},"ISSN":["0302-9743","1611-3349"],"issn-type":[{"type":"print","value":"0302-9743"},{"type":"electronic","value":"1611-3349"}],"subject":[],"published":{"date-parts":[[2018]]}}}