{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,9,5]],"date-time":"2024-09-05T20:51:05Z","timestamp":1725569465116},"reference-count":33,"publisher":"Wiley","issue":"8","license":[{"start":{"date-parts":[[2014,9,8]],"date-time":"2014-09-08T00:00:00Z","timestamp":1410134400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Quality & Reliability Eng"],"published-print":{"date-parts":[[2015,12]]},"abstract":"The performance of control charts can be adversely affected when based on parameter estimates instead of known in\u2010control parameters. Several studies have shown that a large number of phase I observations may be needed to achieve the desired in\u2010control statistical performance. However, practitioners use different phase I samples and thus different parameter estimates to construct their control limits. As a consequence, there would be in\u2010control average run length (ARL) variation between different practitioners. This kind of variation is important to consider when studying the performance of control charts with estimated parameters. Most of the previous literature has relied primarily on the expected value of the ARL (AARL) metric in studying the performance of control charts with estimated parameters. Some recent studies, however, considered the standard deviation of the ARL metric to study the performance of control charts. In this paper, the standard deviation of the ARL metric is used to study the in\u2010control and out\u2010of\u2010control performance of the adaptive exponentially weighted moving average (AEWMA) control chart. The performance of the AEWMA chart is then compared with that of the Shewhart \n and EWMA control charts. The simulation results show that the AEWMA chart might represent a good solution for practitioners to achieve a reasonable amount of ARL variation from the desired in\u2010control ARL performance. In addition, we apply a bootstrap\u2010based design approach that provides protection against frequent false alarms without deteriorating too much the out\u2010of\u2010control performance. Copyright \u00a9 2014 John Wiley & Sons, Ltd.<\/jats:p>","DOI":"10.1002\/qre.1695","type":"journal-article","created":{"date-parts":[[2014,9,9]],"date-time":"2014-09-09T01:19:32Z","timestamp":1410225572000},"page":"1611-1622","source":"Crossref","is-referenced-by-count":69,"title":["A Reevaluation of the Adaptive Exponentially Weighted Moving Average Control Chart When Parameters are Estimated"],"prefix":"10.1002","volume":"31","author":[{"given":"Aya A.","family":"Aly","sequence":"first","affiliation":[{"name":"Department of Statistics, Faculty of Economics and Political Science Cairo University Cairo Egypt"}]},{"given":"Nesma A.","family":"Saleh","sequence":"additional","affiliation":[{"name":"Department of Statistics, Faculty of Economics and Political Science Cairo University Cairo Egypt"}]},{"given":"Mahmoud A.","family":"Mahmoud","sequence":"additional","affiliation":[{"name":"Department of Statistics, Faculty of Economics and Political Science Cairo University Cairo Egypt"}]},{"given":"William H.","family":"Woodall","sequence":"additional","affiliation":[{"name":"Department of Statistics Virginia Tech Blacksburg VA 24061 USA"}]}],"member":"311","published-online":{"date-parts":[[2014,9,8]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"publisher","DOI":"10.1198\/004017003000000023"},{"key":"e_1_2_7_3_1","volume-title":"Introduction to Statistical Quality Control","author":"Montgomery DC","year":"2009"},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.1080\/03610928108828152"},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.1080\/00224065.1993.11979470"},{"issue":"3","key":"e_1_2_7_6_1","first-page":"789","article-title":"The mean and standard deviation of the run length distribution of \n charts when control limits are estimated","volume":"7","author":"Chen G","year":"1997","journal-title":"Statistica Sinica"},{"key":"e_1_2_7_7_1","doi-asserted-by":"publisher","DOI":"10.1080\/03610910008813602"},{"issue":"2","key":"e_1_2_7_8_1","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1080\/00224065.2001.11980067","article-title":"On estimating \n control chart limits","volume":"33","author":"Nedumaran G","year":"2001","journal-title":"Journal of Quality Technology"},{"key":"e_1_2_7_9_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00170-004-2471-2"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1198\/004017001750386279"},{"key":"e_1_2_7_11_1","doi-asserted-by":"publisher","DOI":"10.1002\/qre.1408"},{"key":"e_1_2_7_12_1","doi-asserted-by":"publisher","DOI":"10.1080\/00224065.2004.11980254"},{"key":"e_1_2_7_13_1","doi-asserted-by":"publisher","DOI":"10.1080\/00224065.2006.11918623"},{"key":"e_1_2_7_14_1","doi-asserted-by":"publisher","DOI":"10.1002\/qre.1556"},{"key":"e_1_2_7_15_1","doi-asserted-by":"publisher","DOI":"10.1080\/02669760310001619369"},{"key":"e_1_2_7_16_1","doi-asserted-by":"publisher","DOI":"10.1007\/978-1-4612-1686-5"},{"key":"e_1_2_7_17_1","article-title":"Effect of the number and size of the phase I sample on the phase II performance of S\n 2 and S control charts","author":"Epprecht EK","year":"2014","journal-title":"Journal of Quality Technology"},{"key":"e_1_2_7_18_1","doi-asserted-by":"publisher","DOI":"10.1093\/intqhc\/mzr082"},{"key":"e_1_2_7_19_1","doi-asserted-by":"publisher","DOI":"10.1002\/qre.1304"},{"key":"e_1_2_7_20_1","doi-asserted-by":"publisher","DOI":"10.1002\/qre.1495"},{"key":"e_1_2_7_21_1","doi-asserted-by":"publisher","DOI":"10.1002\/qre.1413"},{"key":"e_1_2_7_22_1","article-title":"The difficulty in designing Shewhart \n and X control charts with estimated parameters","author":"Saleh NA","year":"2014","journal-title":"Journal of Quality Technology"},{"key":"e_1_2_7_23_1","unstructured":"SalehNA MahmoudMA Jones\u2010FarmerLA WoodallWH.Another look at the EWMA control chart with estimated parameters.Submitted manuscript2014b."},{"key":"e_1_2_7_24_1","doi-asserted-by":"publisher","DOI":"10.1080\/03610918.2013.821484"},{"key":"e_1_2_7_25_1","doi-asserted-by":"publisher","DOI":"10.1002\/sjos.12006"},{"key":"e_1_2_7_26_1","doi-asserted-by":"publisher","DOI":"10.1080\/00224065.2002.11980158"},{"key":"e_1_2_7_27_1","doi-asserted-by":"publisher","DOI":"10.1080\/03610918.2010.518269"},{"key":"e_1_2_7_28_1","doi-asserted-by":"publisher","DOI":"10.1198\/004017005000000229"},{"key":"e_1_2_7_29_1","doi-asserted-by":"publisher","DOI":"10.1080\/00401706.1959.10489860"},{"key":"e_1_2_7_30_1","doi-asserted-by":"publisher","DOI":"10.1080\/00401706.1990.10484583"},{"key":"e_1_2_7_31_1","doi-asserted-by":"publisher","DOI":"10.1198\/004017005000000256"},{"key":"e_1_2_7_32_1","doi-asserted-by":"publisher","DOI":"10.1080\/00224065.2010.11917832"},{"key":"e_1_2_7_33_1","doi-asserted-by":"publisher","DOI":"10.1080\/00224065.1999.11979913"},{"key":"e_1_2_7_34_1","doi-asserted-by":"publisher","DOI":"10.1080\/00224065.2009.11917794"}],"container-title":["Quality and Reliability Engineering International"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fqre.1695","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/qre.1695","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,3]],"date-time":"2023-10-03T12:20:10Z","timestamp":1696335610000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/qre.1695"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,9,8]]},"references-count":33,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2015,12]]}},"alternative-id":["10.1002\/qre.1695"],"URL":"https:\/\/doi.org\/10.1002\/qre.1695","archive":["Portico"],"relation":{},"ISSN":["0748-8017","1099-1638"],"issn-type":[{"value":"0748-8017","type":"print"},{"value":"1099-1638","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,9,8]]}}}