Abdominal aortic aneurysm risk of rupture: patient-specific FSI simulations using anisotropic model
- PMID: 19154060
- DOI: 10.1115/1.3005200
Abdominal aortic aneurysm risk of rupture: patient-specific FSI simulations using anisotropic model
Abstract
Abdominal aortic aneurysm (AAA) rupture represents a major cardiovascular risk, combining complex vascular mechanisms weakening the abdominal artery wall coupled with hemodynamic forces exerted on the arterial wall. At present, a reliable method to predict AAA rupture is not available. Recent studies have introduced fluid structure interaction (FSI) simulations using isotropic wall properties to map regions of stress concentrations developing in the aneurismal wall as a much better alternative to the current clinical criterion, which is based on the AAA diameter alone. A new anisotropic material model of AAA that closely matches observed biomechanical AAA material properties was applied to FSI simulations of patient-specific AAA geometries in order to develop a more reliable predictor for its risk of rupture. Each patient-specific geometry was studied with and without an intraluminal thrombus (ILT) using two material models-the more commonly used isotropic material model and an anisotropic material model-to delineate the ILT contribution and the dependence of stress distribution developing within the aneurismal wall on the material model employed. Our results clearly indicate larger stress values for the anisotropic material model and a broader range of stress values as compared to the isotropic material, indicating that the latter may underestimate the risk of rupture. While the locations of high and low stresses are consistent in both material models, the differences between the anisotropic and isotropic models become pronounced at large values of strain-a range that becomes critical when the AAA risk of rupture is imminent. As the anisotropic model more closely matches the biomechanical behavior of the AAA wall and resolves directional strength ambiguities, we conclude that it offers a more reliable predictor of AAA risk of rupture.
Similar articles
-
Intraluminal thrombus and risk of rupture in patient specific abdominal aortic aneurysm - FSI modelling.Comput Methods Biomech Biomed Engin. 2009 Feb;12(1):73-81. doi: 10.1080/10255840903077170. Comput Methods Biomech Biomed Engin. 2009. PMID: 18651282
-
Progression of abdominal aortic aneurysm towards rupture: refining clinical risk assessment using a fully coupled fluid-structure interaction method.Ann Biomed Eng. 2015 Jan;43(1):139-53. doi: 10.1007/s10439-014-1224-0. Epub 2014 Dec 20. Ann Biomed Eng. 2015. PMID: 25527320 Free PMC article.
-
A decoupled fluid structure approach for estimating wall stress in abdominal aortic aneurysms.J Biomech. 2007;40(2):367-77. doi: 10.1016/j.jbiomech.2005.12.013. Epub 2006 Feb 28. J Biomech. 2007. PMID: 16500664
-
[Rupture risk of abdominal aortic aneurysms. The role of computational mechanics].Herz. 2008 Jul;33(5):354-61. doi: 10.1007/s00059-008-3067-7. Epub 2008 Sep 5. Herz. 2008. PMID: 18773155 Review. German.
-
Computational evaluation of aortic aneurysm rupture risk: what have we learned so far?J Endovasc Ther. 2011 Apr;18(2):214-25. doi: 10.1583/10-3244.1. J Endovasc Ther. 2011. PMID: 21521062 Review.
Cited by
-
Detection of Aortic Wall Inclusion Using Regional Pulse Wave Propagation and Velocity In Silico.Artery Res. 2012 Sep;6(3):10.1016/j.artres.2012.05.004. doi: 10.1016/j.artres.2012.05.004. Artery Res. 2012. PMID: 24235978 Free PMC article.
-
Quantification of Arterial Wall Inhomogeneity Size, Distribution, and Modulus Contrast Using FSI Numerical Pulse Wave Propagation.Artery Res. 2014 Jun 1;8(2):57-65. doi: 10.1016/j.artres.2014.01.006. Artery Res. 2014. PMID: 24795784 Free PMC article.
-
Patient-Specific Haemodynamic Analysis of Virtual Grafting Strategies in Type-B Aortic Dissection: Impact of Compliance Mismatch.Cardiovasc Eng Technol. 2024 Jun;15(3):290-304. doi: 10.1007/s13239-024-00713-6. Epub 2024 Mar 4. Cardiovasc Eng Technol. 2024. PMID: 38438692 Free PMC article.
-
Intracranial aneurysmal pulsatility as a new individual criterion for rupture risk evaluation: biomechanical and numeric approach (IRRAs Project).AJNR Am J Neuroradiol. 2014 Sep;35(9):1765-71. doi: 10.3174/ajnr.A3949. Epub 2014 May 22. AJNR Am J Neuroradiol. 2014. PMID: 24852288 Free PMC article.
-
Medical Image-Based Computational Fluid Dynamics and Fluid-Structure Interaction Analysis in Vascular Diseases.Front Bioeng Biotechnol. 2022 Apr 27;10:855791. doi: 10.3389/fbioe.2022.855791. eCollection 2022. Front Bioeng Biotechnol. 2022. PMID: 35573253 Free PMC article. Review.
MeSH terms
LinkOut - more resources
Full Text Sources
Research Materials