Cross calibration of ocean-color bands from moderate resolution imaging spectroradiometer on Terra platform
- PMID: 19104531
- DOI: 10.1364/ao.47.006796
Cross calibration of ocean-color bands from moderate resolution imaging spectroradiometer on Terra platform
Abstract
Ocean-color applications require maximum uncertainties in blue-wavelength water-leaving radiances in oligotrophic ocean of approximately 5%. Water-leaving radiances from Moderate Resolution Imaging Spectroradiometer (MODIS) on the Terra satellite, however, exhibit temporal drift of the order of 15% as well as sensor changes in response versus scan and polarization sensitivity, which cannot be tracked by onboard calibrators. This paper introduces an instrument characterization approach that uses Earth-view data as a calibration source. The approach models the top of the atmosphere signal over ocean that the instrument is expected to measure, including its polarization, with water-leaving radiances coming from another well-calibrated global sensor. The cross calibration allows for significant improvement in derived MODIS-Terra ocean-color products, with largest changes in the blue wavelengths.
Similar articles
-
Adjustment of ocean color sensor calibration through multi-band statistics.Opt Express. 2010 Jan 18;18(2):401-12. doi: 10.1364/OE.18.000401. Opt Express. 2010. PMID: 20173860
-
Spectral interdependence of remote-sensing reflectance and its implications on the design of ocean color satellite sensors.Appl Opt. 2014 May 20;53(15):3301-10. doi: 10.1364/AO.53.003301. Appl Opt. 2014. PMID: 24922219
-
Ocean color products from the Korean Geostationary Ocean Color Imager (GOCI).Opt Express. 2013 Feb 11;21(3):3835-49. doi: 10.1364/OE.21.003835. Opt Express. 2013. PMID: 23481840
-
A decade of satellite ocean color observations.Ann Rev Mar Sci. 2009;1:19-42. doi: 10.1146/annurev.marine.010908.163650. Ann Rev Mar Sci. 2009. PMID: 21141028 Review.
-
Photon spectrometry in mixed fields.Radiat Prot Dosimetry. 2003;107(1-3):125-31. doi: 10.1093/oxfordjournals.rpd.a006381. Radiat Prot Dosimetry. 2003. PMID: 14756172 Review. No abstract available.
Cited by
-
Assessing the fitness-for-purpose of satellite multi-mission ocean color climate data records: A protocol applied to OC-CCI chlorophyll-a data.Remote Sens Environ. 2017 Dec 15;203:139-151. doi: 10.1016/j.rse.2017.03.039. Remote Sens Environ. 2017. PMID: 29276312 Free PMC article.
-
Exploring systematic offsets between aerosol products from the two MODIS sensors.Atmos Meas Tech. 2018 Jul;11(7):4073-4092. doi: 10.5194/amt-11-4073-2018. Epub 2018 Jul 13. Atmos Meas Tech. 2018. PMID: 32676129 Free PMC article.
-
Aqua and Terra MODIS RSB calibration comparison using BRDF modeled reflectance.IEEE Trans Geosci Remote Sens. 2017 Apr;55(4):2288-2298. doi: 10.1109/TGRS.2016.2641258. Epub 2017 Jan 16. IEEE Trans Geosci Remote Sens. 2017. PMID: 32742051 Free PMC article.
-
Satellite Ocean Colour: Current Status and Future Perspective.Front Mar Sci. 2019 Aug 29;6:1-30. doi: 10.3389/fmars.2019.00485. Front Mar Sci. 2019. PMID: 36817748 Free PMC article.
-
An example of aerosol pattern variability over bright surface using high resolution MODIS MAIAC: The eastern and western areas of the Dead Sea and environs.Atmos Environ (1994). 2017 Sep;165:359-369. doi: 10.1016/j.atmosenv.2017.06.047. Epub 2017 Jun 29. Atmos Environ (1994). 2017. PMID: 29773961 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources