Cone beam volume CT image artifacts caused by defective cells in x-ray flat panel imagers and the artifact removal using a wavelet-analysis-based algorithm
- PMID: 11393477
- DOI: 10.1118/1.1368878
Cone beam volume CT image artifacts caused by defective cells in x-ray flat panel imagers and the artifact removal using a wavelet-analysis-based algorithm
Abstract
The application of x-ray flat panel imagers (FPIs) in cone beam volume CT (CBVCT) has attracted increasing attention. However, due to a deficient semiconductor array manufacturing process, defective cells unavoidably exist in x-ray FPIs. These defective cells cause their corresponding image pixels in a projection image to behave abnormally in signal gray level, and result in severe streak and ring artifacts in a CBVCT image reconstructed from the projection images. Since a three-dimensional (3-D) back-projection is involved in CBVCT, the formation of the streak and ring artifacts is different from that in the two-dimensional (2-D) fan beam CT. In this paper, a geometric analysis of the abnormality propagation in the 3D back-projection is presented, and the morphology of the streak and ring artifacts caused by the abnormality propagation is investigated through both computer simulation and phantom studies. In order to calibrate those artifacts, a 2D wavelet-analysis-based statistical approach to correct the abnormal pixels is proposed. The approach consists of three steps: (1) the location-invariant defective cells in an x-ray FPI are recognized by applying 2-D wavelet analysis on flat-field images, and a comprehensive defective cell template is acquired; (2) based upon the template, the abnormal signal gray level of the projection image pixels corresponding to the location-invariant defective cells is replaced with the interpolation of that of their normal neighbor pixels; (3) that corresponding to the isolated location-variant defective cells are corrected using a narrow-windowed median filter. The CBVCT images of a CT low-contrast phantom are employed to evaluate this proposed approach, showing that the streak and ring artifacts can be reliably eliminated. The novelty and merit of the approach are the incorporation of the wavelet analysis whose intrinsic multi-resolution analysis and localizability make the recognition algorithm robust under variable x-ray exposure levels between 30% and 70% of the dynamic range of an x-ray FPI.
Similar articles
-
High-quality 3D correction of ring and radiant artifacts in flat panel detector-based cone beam volume CT imaging.Phys Med Biol. 2011 Oct 7;56(19):6495-519. doi: 10.1088/0031-9155/56/19/020. Epub 2011 Sep 20. Phys Med Biol. 2011. PMID: 21934193
-
Comparison of ring artifact removal methods using flat panel detector based CT images.Biomed Eng Online. 2011 Aug 17;10:72. doi: 10.1186/1475-925X-10-72. Biomed Eng Online. 2011. PMID: 21846411 Free PMC article.
-
Flat-panel cone-beam computed tomography for image-guided radiation therapy.Int J Radiat Oncol Biol Phys. 2002 Aug 1;53(5):1337-49. doi: 10.1016/s0360-3016(02)02884-5. Int J Radiat Oncol Biol Phys. 2002. PMID: 12128137
-
Principles and concepts of computed tomography.Vet Clin North Am Small Anim Pract. 1993 Mar;23(2):399-415. doi: 10.1016/s0195-5616(93)50034-7. Vet Clin North Am Small Anim Pract. 1993. PMID: 8465497 Review.
-
An outlook on x-ray CT research and development.Med Phys. 2008 Mar;35(3):1051-64. doi: 10.1118/1.2836950. Med Phys. 2008. PMID: 18404940 Review.
Cited by
-
Effect of scattered megavoltage x-rays on markerless tumor tracking using dual energy kilovoltage imaging.J Appl Clin Med Phys. 2023 Aug;24(8):e13993. doi: 10.1002/acm2.13993. Epub 2023 Apr 18. J Appl Clin Med Phys. 2023. PMID: 37071500 Free PMC article.
-
A novel total variation based ring artifact suppression method for CBCT imaging with two-dimensional antiscatter grids.Med Phys. 2019 May;46(5):2181-2193. doi: 10.1002/mp.13456. Epub 2019 Mar 20. Med Phys. 2019. PMID: 30802970 Free PMC article.
-
John's Equation-based Consistency Condition and Corrupted Projection Restoration in Circular Trajectory Cone Beam CT.Sci Rep. 2017 Jul 7;7(1):4920. doi: 10.1038/s41598-017-05249-5. Sci Rep. 2017. PMID: 28687756 Free PMC article.
-
A Ring Artifact Correction Method: Validation by Micro-CT Imaging with Flat-Panel Detectors and a 2D Photon-Counting Detector.Sensors (Basel). 2017 Jan 30;17(2):269. doi: 10.3390/s17020269. Sensors (Basel). 2017. PMID: 28146088 Free PMC article.
-
Evaluation of a Wobbling Method Applied to Correcting Defective Pixels of CZT Detectors in SPECT Imaging.Sensors (Basel). 2016 May 27;16(6):772. doi: 10.3390/s16060772. Sensors (Basel). 2016. PMID: 27240368 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical